Results 41 to 50 of about 163 (147)
Static VAr Compensators can provide significant improvement in power system stability. Phasor Measurement Units are used in combination with SVCs for fast and reliable control of its operation. By combining the VAr control and Voltage Regulation control methods of the SVC, superior performance is obtained.
Faris Alsalem, Ayman Faza
wiley +1 more source
Metal-oxide-varistor (MOV) devices, connected in parallel have been used to protect the series compensation against overvoltage during faults. The MOV-protected series compensation increases the complexity of fault analysis and device protection. Hence the performance evaluation of distance protection scheme in the presence of Flexible Alternating ...
Ezendiokwelu C E +2 more
openaire +2 more sources
Series and Shunt Reactive compensation can be used to improve voltage stability. The L‐index and Fast Voltage Stability Index are used to evaluate stability. Cost of reactive compensation is included directly in the optimization process. Multi‐objective optimization determines the optimal sizing of FACTS devices.
Rawan Abu Zeitawyeh, Ayman Faza
wiley +1 more source
In present time the power demand increases more rapidly in the power generation and transmission and distribution system sectors. For maintaining the power system stability and steady state operation of power systems causes from disturbance, faults and ...
Bindeshwar Singh, Rajesh Kumar
doaj +1 more source
Orthogonal Multi‐swarm Greedy Selection Sine Cosine Algorithm (OMGSCA) effectively optimizes FACTS placement and sizing in wind‐integrated power systems, reducing operational costs and power losses while enhancing grid stability. Tested on the IEEE 30‐bus system, OMGSCA outperforms traditional methods, demonstrating superior exploration, exploitation ...
Sunilkumar P. Agrawal +6 more
wiley +1 more source
Power Flow Control in Power System Using FACT Device Thyristor Controlled Series Capacitor (TCSC)
In modern days due to the ever increasing demand for power in expansion of transmission network, the transmission line are to be operated under loaded condition and there is a risk of power flow control and voltage instability. This paper proposes power flow control in a power system network by incorporating TCSC and SVC devices.
openaire +1 more source
The impedance sensitivity of the doubly‐fed induction generator (DFIG) grid‐connected system with series compensation is analysed using the Morris method and the extended Fourier amplitude sensitivity test (EFAST). A cooperative optimisation approach is proposed to adjust high‐sensitivity parameters, thereby suppressing sub‐synchronous oscillations ...
Gaojun Meng +5 more
wiley +1 more source
This paper introduces the Adaptive Coordinated Fixed-Time Synergetic Controller (ACFSC) designed for the Thyristor Controlled Series Capacitor (TCSC) and the generator excitation system.
Arman Fathollahi, Bjorn Andresen
doaj +1 more source
Optimal reactive power dispatch considering multi-type FACTS devices using harmony search algorithms
Optimal Reactive Power Dispatch (ORPD) plays an important role for the secure and reliable operation of power systems. The main purpose of ORPD is to find the settings of control variables such as voltage rating of generators, reactive power injection of
D. Karthikaikannan, G. Ravi
doaj +1 more source
This paper presents a TID‐based PSS optimized by MRFOSSA, ensuring robust stability in power systems, validated through WSCC‐3 machines 9‐bus system. Abstract This paper emphasizes the significance of ensuring adequate damping of electromechanical oscillations in power systems to ensure stable operation.
Mohamed H. Hassan +4 more
wiley +1 more source