Results 1 to 10 of about 141 (107)
UEG Week 2025 Moderated Posters [PDF]
United European Gastroenterology Journal, Volume 13, Issue S8, Page S189-S802, October 2025.
europepmc +2 more sources
The optimal setting of directional overcurrent relays (DOCRs) ensures the fault detection and clearing in the minimum possible operation time. Directional protective relaying is carried out to coordinate relay settings in a meshed network in the presence
Pegah Alaee, Turaj Amraee
doaj +1 more source
The safety and reliability of an electrical network depend on the performance of the protections utilized. Therefore, the optimal coordination of the protective devices plays an essential role.
Khaled Guerraiche +3 more
doaj +1 more source
To reduce damage to electrical power equipment, protective equipment is needed that is designed as well as possible, so that the protection relay can isolate faults in parts of the distribution network as fast as possible.
Andy Frediansyah +2 more
doaj +1 more source
Per-Phase and 3-Phase Optimal Coordination of Directional Overcurrent Relays Using Genetic Algorithm
Penetration of the power grid by renewable energy sources, distributed storage, and distributed generators is becoming increasingly common. Increased utilization of these distributed energy resources (DERs) has given rise to additional protection ...
Ronald C. Matthews +4 more
doaj +1 more source
This paper presents an improved inverse-time over-current protection method based on the compound fault acceleration factor and the beetle antennae search (BAS) optimization method for a microgrid.
Liang Ji +7 more
doaj +1 more source
Integration of distributed generators (DGs) into a distribution network (DN) can cause coordination challenges of overcurrent relays (OCRs) because of different fault-current contributions of DGs as well as the directional change in fault currents ...
Duong Minh Bui +3 more
doaj +1 more source
The use of distribution generators affects fault currents, leading to miscoordination between protection relays and causing constraints on network reliability. To tackle this issue, an adaptive protection scheme (APS) based on a modified pelican optimization algorithm (MPOA) and active database management system is proposed.
Mohamed Abdelhamid +2 more
wiley +1 more source
• Sitting and sizing of synchronous distributed generations (SDGs) in the distribution network (DN) constrained to maintain the protection coordination of overcurrent relays (OCRs), • Simultaneous modelling of operation, voltage security, economic and protection coordination indices in the planning of SDGs in the DN,• Eliminating the protection re ...
Hossien Shad +2 more
wiley +1 more source
This paper is aimed at recloser‐fuse protection in CESS employed multi‐microgrid distribution systems for improving the fuse saving task and mitigating the fault resistance effects. In this way, after applying the conventional recloser‐fuse protection scheme, a new scheme is presented to improve the performance of the system in presence of CESS and ...
Amin Yazdaninejadi, Hossein Ebrahimi
wiley +1 more source

