Results 151 to 160 of about 158,286 (311)
The complex tip flow instability and its induced non-synchronous vibration have become significant challenges, especially as aerodynamic loading continues to increase.
Songbai Wang, Yong Chen, Yadong Wu
doaj +1 more source
An Experimental Investigation of the Flow Physics Associated With End Wall Losses and Large Rotor Tip Clearances as Found in the Rear Stages of a High Pressure Compressor [PDF]
The focus of this work was to characterize the fundamental flow physics and the overall performance effects due to increased rotor tip clearance heights in axial compressors. Data have been collected in the three-stage axial research compressor at Purdue
Berdanier, Reid A., Key, Nicole L.
core +1 more source
Surface Diffusion in SnTe‐PbTe Monolayer Lateral Heterostructures
The lateral heterostructures between 2D materials often suffer from the interdiffusion at the interfaces. Here, a surface diffusion mechanism is found to be dominating at the interfaces between semiconducting SnTe and PbTe monolayers. Atomically sharp interfaces can be achieved by suppressing this diffusion process. ABSTRACT The construction of complex
Jing‐Rong Ji +9 more
wiley +1 more source
JT9D performance deterioration results from a simulated aerodynamic load test [PDF]
The results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance are presented. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance ...
Stakolich, E. G., Stromberg, W. J.
core +1 more source
This study demonstrates coherent control of 15N nuclear spins coupled to VB−${\text{V}}_{\text{B}}^{-}$ centers in isotope‐enriched hexagonal boron nitride. Selective addressing via spin‐state mixing enables Rabi driving, quantum gates, and coherence times exceeding 10 μs$\umu{\rm s}$.
Adalbert Tibiássy +6 more
wiley +1 more source
The effect of flow coefficient on the design of miniature centrifugal impeller [PDF]
This paper was presented at the 3rd Micro and Nano Flows Conference (MNF2011), which was held at the Makedonia Palace Hotel, Thessaloniki in Greece.
3rd Micro and Nano Flows Conference (MNF2011) +2 more
core
Cardiac‐Derived ECM Microspheres for Enhanced hiPSC‐CMs Maturation
Cardiac extracellular matrix microspheres derived from decellularized porcine heart provide a biomimetic 3D microenvironment for human induced pluripotent stem cell–derived cardiomyocytes (hiPSC‐CMs). This platform supports short‐ and long‐term culture, enhances structural organization, and promotes electrophysiological and functional maturation of ...
Jiazhu Xu +9 more
wiley +1 more source
Development of a transparent, self‐sanitizing antimicrobial coating technology applicable to a wide range of materials and surfaces‐including touchscreens, transparent substrates, and metal, plastic, and glass‐regardless of pathogen type. The spray‐coated, UV‐cross‐linked imidazole‐based quaternary ammonium chloride materials provide broad‐spectrum ...
Surjith Kumaran +6 more
wiley +1 more source
Performance of a tandem-rotor/tandem-stator conical-flow compressor designed for a pressure ratio of 3 [PDF]
A conical-flow compressor stage with a large radius change through the rotor was tested at three values of rotor tip clearance. The stage had a tandem rotor and a tandem stator. Peak efficiency at design speed was 0.774 at a pressure ratio of 2.613.
Owen, A. K. +2 more
core +1 more source
A 3D nanowire‐network SERS substrate with robust adhesion is developed, featuring pronounced z‐direction optical activity, ultralow detection limit (1.5 × 10−13 M), and excellent signal uniformity (RSD < 10%). Enabled by enhanced light scattering, increased optical density of states, and structural reinforcement, the substrate demonstrates stable, high‐
Jinglai Duan +6 more
wiley +1 more source

