Evaluation of agreement of IOP measurements by Tono-Vera tonometer to Goldmann applanation tonometry
PurposeTo evaluate the accuracy of the new Tono-Vera rebound tonometer (Reichert Inc, Buffalo, NY) compared to Goldmann Applanation Tonometry.MethodsThis prospective, observational, cross-sectional study was designed in accordance with ANSI Z80.10-2014 ...
Charles R. Niles +3 more
doaj +1 more source
This study aimed to compare values of intraocular pressure (IOP) by different tonometers and evaluators (veterinary ophthalmologist specialist and veterinary not a specialist).
Vinícius Thomaz da Silva Almeida +7 more
doaj
Does Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes?
Purpose. To examine the influence of positional misalignments on intraocular pressure (IOP) measurement with a rebound tonometer. Methods. Using the iCare rebound tonometer, IOP readings were taken from the right eye of 36 healthy subjects at the central
Ian G. Beasley +5 more
doaj +1 more source
The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma
PURPOSE: To compare intraocular pressure (IOP) measurements obtained using the new rebound tonometer Icare-Pro and the hand-held version of Goldmann Applanation Tonometer (Perkins tonometer) in children with primary congenital glaucoma (PCG) under ...
Morales Fernández, Laura +5 more
core +1 more source
Ocular hypertension induces early hyperactivity in inner retinal inhibitory circuitry before substantial retinal ganglion cell loss. Sustained pharmacological inhibition of GABAergic/glycinergic neurotransmission and Vgat‐targeted Lin28 expression suppress this hyperactivity and improve RGC survival without reducing intraocular pressure. These findings
Eunji Hong +7 more
wiley +1 more source
Objective: To compare the validity and agreement of the central corneal thickness (CCT) corrected intraocular pressure (IOP) measurements of noncontact Pulsair and iCare tonometers, using Perkins applanation tonometer (PAT) as a reference tonometer in ...
Ogochukwu Adaora Sibeudu +3 more
doaj +1 more source
POSTÜR DEĞİŞİKLİKLERİNİN GÖZİÇİ BASINCINA ETKİSİ
Amaç: Vücut postüründeki değişikliklerin göziçi basıncına etkisinin incelenmesiGereç-Yöntem: İntravitreal enjeksiyon planlanan 67 erkek,83 kadın 150 hastanın 150 gözü değerlendirmeye alındı.Hastaların ayaktayken(AGİB),otururken(OGİB) ve sırtüstü yatar ...
Mehmet Coşkun
doaj +1 more source
ABSTRACT Background Automated vertical cup‐to‐disc ratio (VCDR) measurements are commonly used in optic nerve assessment, but measurements may vary across optical coherence tomography (OCT) platforms, particularly in eyes with atypical optic nerve anatomy such as optic nerve head drusen (ONHD).
Sedra T. Alabed +3 more
wiley +1 more source
Nathan Radcliffe,1 John Berdahl,2 Mitchel Ibach,2 Justin Schweitzer,2 Jason Levine,3 Sean McCafferty3 1New York Eye Surgery Center, New York, NY, USA; 2Vance Thompson Vision, Sioux Falls, SD, USA; 3Arizona Eye Consultants, Tucson, AZ, USACorrespondence ...
Radcliffe N +5 more
doaj
Summary Introduction Reliable continuous non‐invasive blood pressure monitoring technology should support clinicians to maintain blood pressure within appropriate limits peri‐operatively. Previous studies have shown conflicting results regarding measurement accuracy.
Stefanie Lischker +3 more
wiley +1 more source