Results 51 to 60 of about 16,583 (168)

Ex vivo and in vivo study of Kowa HA-2 applanation tonometer in the measurement of intraocular pressure in dogs

open access: yesSemina: Ciências Agrárias, 2016
The objective of this study was to evaluate the use of the Kowa HA-2 applanation tonometer in measuring intraocular pressure (IOP) in dogs. Twenty eyes were used in an ex vivo study in which the calibration curve for manometry vs.
Silvia Franco Andrade   +6 more
doaj   +1 more source

Grade of tear meniscus height, intraocular pressure measured with non-contact tonometer and Goldmann applanation tonometer.

open access: yes, 2019
Grade of tear meniscus height, intraocular pressure measured with non-contact tonometer and Goldmann applanation tonometer.
Bo Ram Seol (7387829)   +2 more
core   +1 more source

Comparison of exercise training and repeated hot water immersion on vascular function in overweight older adults

open access: yesExperimental Physiology, EarlyView.
Abstract Recent studies suggest that heat exposure may benefit cardiovascular health, but in overweight and obese older adults, the chronic effects of heat therapy on artery function are still uncertain. We aimed to compare the effects of 12 weeks (3×/week, 40 min) of aerobic exercise (EXE) to hot water immersion (HWI) and an inactive control group ...
Juliene G. Costa   +6 more
wiley   +1 more source

Intraocular pressure measurement and association with corneal biomechanics in patients underwent Descemet’s stripping with endothelial keratoplasty: a comparative study

open access: yesFrontiers in Medicine
PurposeTo compare corneal biomechanical properties and intraocular pressure (IOP) measurements in patients who underwent Descemet’s stripping with endothelial keratoplasty (DSEK) with those of the follow healthy eyes.MethodsIn this retrospective ...
Huiyu Chen   +21 more
doaj   +1 more source

Comparative study of measurement of intraocular pressure in eyes with corneal opacity and normal cornea by Tonopen Avia, rebound tonometer (I-care), and noncontact tonometer

open access: yesJournal of Marine Medical Society, 2020
Purpose: The most common indications for keratoplasty are patients with corneal opacity. The presence of glaucoma prior to keratoplasty is an important risk factor, eventually may lead to failure of the corneal graft.
Sridhara Reddy   +3 more
doaj   +1 more source

Avaliação das técnicas de antissepsia bacteriana do cone de aplanação dos tonômetros de goldmann em uso em consultórios e Hospitais da grande Florianópolis. [PDF]

open access: yes, 2006
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina. Curso de Medicina.
Daguano, Carolina Rottili
core  

Continuous duty tonometer system

open access: yes, 1965
This tonometer system, for equilibration of blood or other biological fluids, consists of a constant temperature bath which houses four independent tonometer flasks.
L. E. Farhi
core   +1 more source

The influence of haemoglobin–O2 affinity on aerobic capacity in hypoxia in high‐altitude deer mice (Peromyscus maniculatus)

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend The influence of haemoglobin–O2 affinity on aerobic capacity in hypoxia has been contentious. Many high‐altitude natives have greater haemoglobin–O2 affinity (lower P50, the O2 pressure at 50% haemoglobin saturation) than their low‐altitude counterparts, but the advantages of this change for aerobic metabolism have often remained
Kayla M. Garvey, Graham R. Scott
wiley   +1 more source

Limbal cystotomy by fine needle aspiration of a translucent iris cyst in a horse

open access: yesEquine Veterinary Education, Volume 38, Issue 11, Page e784-e789, November 2026.
Summary A 4‐year‐old Cremello crossbred mare was referred to the Equine Veterinary Teaching Hospital of Utrecht University for a translucent iris cyst from the dorsal pupillary margin corpora nigra in the right eye. Although noninvasive diode laser treatment is the preferred method of pigmented cyst ablation, two attempts did not result in disruption ...
A. L. Hendrikx   +5 more
wiley   +1 more source

A Review on Different Tonometers for Intraocular Pressure Measurement After Photorefractive Keratectomy or Small Incision Lenticule Extraction

open access: yesClinical Ophthalmology, 2020
Shing Chuen Chow, Barry Yat Ming Yeung CAP Medical Center, Hong KongCorrespondence: Barry Yat Ming YeungCAP Medical Center, Rm 501-502, Hang Shing Building, 363 Nathan Road, Hong KongTel +852 23329830Fax +852 23326896Email bymyeung@gmail.comAbstract ...
Chow SC, Yeung BYM
doaj  

Home - About - Disclaimer - Privacy