Results 81 to 90 of about 16,583 (168)
Purpose : To compare the level of accuracy of intraocular pressure (IOP) measurements attained by non-contact tonometer (NCT), rebound tonometer (RT) Icare®, and Tono-Pen (TONO-PEN AVIA®), using Goldmann Applanation tonometer (GAT) as a reference value ...
김태임, 김세경, 김응권
core +1 more source
Background: The aim of this study was to compare the intraocular pressure (IOP) results measured by the iCare rebound tonometer with those obtained by the Goldmann applanation tonometer (GAT) over a wide range of IOP values.
Munkwitz, S. ; https://orcid.org/ +4 more
core +1 more source
Comparison of Goldmann applanation tonometer, Tono-Pen and noncontact tonometer in children
Background: To evaluate the agreement of Goldmann applanation tonometer (GAT) with Tono-Pen and noncontact tonometer (NCT) for measurement of intraocular pressure (IOP) in pediatric age group and to evaluate the correlation between central corneal ...
Shantanu Kumar Gupta +4 more
core +1 more source
The results of development of special program and apparatus unit «SPAS» for biomechanical diagnostics of cardiovascular system by oscillometry method have been presented.
S. V. Shil’ko +2 more
doaj
The accurate measurement of intra-ocular pressure (IOP) is an important procedure in the detection and treatment of glaucoma. The Ocular Response Analyser (ORA) and the ICare rebound tonometer are two recent additions to the instruments available to eye ...
Wayne D.H. Gillan
doaj +1 more source
Evaluation of the new Ocuton S tonometer
Purpose: To evaluate the intra- and interobserver variability of the Ocuton S tonometer, its correlation with Goldmann tonometry, the reliability of self-tonometry and the safety of the instrument. Methods: Thirty-five healthy subjects and 45 patients
Sergio Perfetti +7 more
core +1 more source
Kelechi C Ogbuehi, John C Chijuka, Uchechukwu L Osuagwu Department of Optometry & Vision Science, College of Applied Medical Sciences, King Saud University, Riyadh, Kingdom of Saudi ArabiaBackground: The purpose of this study was to evaluate the ...
Ogbuehi KC, Chijuka JC, Osuagwu UL
doaj
Error measurement for a portable tonometer
Most patients with glaucoma exhibit elevated intra-ocular pressure (IOP). A cost effective device that allows the patient to measure IOP at regular intervals may reduce vision loss.
Marchetto, Peter +3 more
core +1 more source
IntroductionTo determine the agreement between intraocular pressure (IOP) measurements using conventional Goldmann applanation tonometry (GA1,2T) and SUOER SW-500 Rebound Tonometer.MethodsThis was a retrospective observational study where 205 eyes of 106
Jia Quan Chaung +6 more
doaj +1 more source
Comparison of Intraocular Pressure Measurement by iCare Tonometer and Goldman Applanation Tonometer
Objective: To compare the Intraocular Pressure measured by the Goldmann Applanation tonometer with by iCare ic100 tonometer in normal human eye to determine the accuracy and reliability of both methods.
Asem Hameed +5 more
doaj +1 more source