Results 1 to 10 of about 52,528 (198)

Custom-Made Artificial Iris and Toric-Intraocular Lens Intrascleral Flange Fixation: A Case Report [PDF]

open access: yesMedicina (Lithuania)
Different techniques for artificial iris implantation with or without an intraocular lens, depending on lens status, are described in the literature.
Ran Moshkovsky
exaly   +5 more sources

Toric intraocular lens: A literature review

open access: yesTaiwan Journal of Ophthalmology, 2021
Toric intraocular lenses (IOLs) are universally recommended in cataract cases with preoperative corneal astigmatism ≥1.5 D. An optimal surgical outcome depends on careful patient selection, complete preoperative evaluation, accurate IOL power calculation,
Mithun Thulasidas, Aishwarya Kadam
doaj   +3 more sources

Effect of Posterior Corneal Surgically Induced Astigmatism on Toric Intraocular Lens Power Calculations. [PDF]

open access: yesClin Ophthalmol
Background To determine whether accounting for posterior corneal surgically induced astigmatism (SIA) would improve toric intraocular lens power calculation prediction error. Methods A total of 189 eyes of 148 patients undergoing routine cataract surgery
Stewart S   +4 more
europepmc   +2 more sources

Comparison of trifocal toric and bifocal toric intraocular lens implantation in patients with cataract and high corneal astigmatism. [PDF]

open access: yesInternational Journal of Ophthalmology, 2021
AIM: To investigate and compare the quality of life, satisfaction, contrast sensitivity, glare, depth perception, and intraocular lens (IOL) rotation in patients who underwent trifocal toric and bifocal toric IOLs.
Erdoğan Yaşar
exaly   +2 more sources

Comparison of toric intraocular lens alignment between femtosecond laser-assisted capsular marking and digital marking. [PDF]

open access: yesJ Cataract Refract Surg, 2023
Femtosecond laser–assisted capsular marking was more precise in toric IOL alignment than digital marking and offered good refractive results. Purpose: To compare the accuracy of toric intraocular lens (IOL) alignment between femtosecond laser–assisted ...
Schultz T, Hoffmann S, Dick HB.
europepmc   +2 more sources

Femtosecond Laser Arcuate Keratotomy vs Toric Intraocular Lens Implantation in Cataract Surgery: A Randomized Clinical Trial.

open access: yesJAMA Ophthalmol
This randomized clinical trial investigates if femtosecond laser arcuate keratotomy is superior to toric intraocular lens implantation to correct astigmatism in patients undergoing femtosecond laser-assisted cataract surgery.
Zhong Y   +7 more
europepmc   +2 more sources

Rotational stability and refractive outcomes of a new hydrophobic acrylic toric intraocular lens. [PDF]

open access: yesEye Vis (Lond)
To assess rotational stability and refractive outcomes of a new toric hydrophobic acrylic intraocular lens (IOL). Single-center, prospective, interventional clinical trial.
Schartmüller D   +9 more
europepmc   +2 more sources

Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens. [PDF]

open access: yesClin Ophthalmol
Purpose To evaluate the visual outcomes and efficacy of astigmatism correction using a new hydrophobic trifocal toric intraocular lens (IOL). Methods This study involved 62 eyes implanted with the FineVision HP Toric IOL.
Daya S, Espinosa Lagana M.
europepmc   +2 more sources

Rotational stability and visual performance of aberration-free, hydrophobic acrylic monofocal toric intraocular lens with enhanced material. [PDF]

open access: yesJ Cataract Refract Surg
The enhanced enVista toric MX60ET IOL showed excellent rotational stability, low residual cylinder, and good uncorrected visual acuity indicating good efficacy of the IOL for astigmatism correction during cataract surgery.
Wiley WF   +5 more
europepmc   +2 more sources

Correction of pre-existing astigmatism with phacoemulsification using toric intraocular lens versus spherical intraocular lens and wave front guided surface ablation

open access: yesBMC Ophthalmology, 2022
Background This study aimed to evaluate toric intraocular lens to correct of pre-existing astigmatism at the time of phacoemulsification compared to using of spherical intraocular lens followed by wavefront guided surface ablation.
Ahmed El-Shehawy   +4 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy