Results 41 to 50 of about 3,150 (209)
Astigmatism management in cataract surgery with Precizon(®) toric intraocular lens: a prospective study [PDF]
PURPOSE: The purpose of this study was to evaluate the visual and refractive outcomes and rotational stability of the new aspheric Precizon(®) toric intraocular lens (IOL) for the correction of corneal astigmatism in cataract surgery.
Lume, M. +7 more
core +1 more source
Time–efficiency assessment of guided toric IOL cataract surgery: a pilot study [PDF]
Submitted: September 11, 2020; Final revision submitted: April 26, 2021; Accepted: April 26, 2021.Purpose: To compare the time spent on toric intraocular lens (IOL) implantation during cataract surgery using a manualmarking vs a digital image–guided ...
Durán, Pablo +7 more
core +1 more source
PurposeTo investigate the dynamic visual acuity (DVA) after implantation of toric bifocal or trifocal intraocular lens in age-related cataract patients.MethodsThis was a prospective randomized controlled trial.
Yuanting Li +14 more
doaj +1 more source
Errors in supplementary toric IOL implantation (Sulcoflex toric, Rayner)
In the article, the results of a combined surgical treatment method of induced astigmatism in a pseudophakic eye are presented. The authors describe an initial case of “wrong” supplementary toric IOL Sulcoflex (Rayner, Great Britain) position and its influence on aberrometric parameters.
Kirill Vladimirovich Khripun +2 more
openaire +2 more sources
Clinical outcomes after implantation of a new hydrophobic acrylic toric IOL during routine cataract surgery [PDF]
PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery.
Bhatt, Uday +6 more
core +1 more source
PURPOSE:To assess the influence of capsular tension ring (CTR) on surgical outcomes of toric and multifocal intraocular lenses (IOLs) in eyes at high risk of zonular instability.
Teruyuki Miyoshi +5 more
doaj +1 more source
Repeatability of keratometry depending on tear film osmolarity
Abstract Purpose To determine the repeatability of keratometry and astigmatism measurements of patients depending on the tear film osmolarity using three different devices. Methods In this study, 97 eyes of 97 patients with a mean age of 64.92 ± 12.07 years received three repeated measurements with the IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany),
David Schneider +4 more
wiley +1 more source
Toric intraocular lenses (IOLs) have been developed to enhance visual acuity impaired by cataracts and correct corneal astigmatism. However, residual astigmatism caused by postoperative rotation of the toric IOL is an important factor affecting visual ...
Xuanqiao Lin +9 more
doaj +1 more source
Optical myopia control interventions: Evaluation of methods and success in a real‐world population
Abstract Purpose To explore methods of evaluating success of optical myopia control interventions, and to apply these methods retrospectively to a clinical population. Methods A retrospective cohort study was conducted on pediatric patients attending a United Kingdom myopia clinic and used defocus incorporated multiple segments (DIMS) spectacle lenses,
Mhairi Day, Stephanie Kearney
wiley +1 more source
Comparison between clinical outcomes of two different designs of toric multifocal intraocular lenses
To compare the clinical outcomes of plate haptic and open-loop haptic toric multifocal intraocular lenses (IOLs). In this retrospective, comparative clinical trial, two different designs of multifocal toric IOL were implanted in 49 eyes of 38 cases with ...
Orhan Ayar +3 more
doaj +1 more source

