Results 81 to 90 of about 5,711 (256)
Cataract phacoemulsification combined with the implantation of the most suitable intraocular lens can improve the visual acuity of visually impaired patients. Visual rehabilitation involves special tools such as microperimetry, prisms, lenses, electronic equipment, and specific neuromodulation techniques that stimulate the brain and neuroretina.
Paolo Giuseppe Limoli +2 more
wiley +1 more source
Rotation Characteristics of Three Toric Monofocal Intraocular Lenses
Brent A Kramer,1 David R Hardten,2 John P Berdahl3 1Department of Ophthalmology, University of North Carolina, Chapel Hill, NC, USA; 2Minnesota Eye Consultants, Minnetonka, MN, USA; 3Vance Thompson Vision, Sioux Falls, SD, USACorrespondence: Brent A ...
Kramer BA, Hardten DR, Berdahl JP
doaj
Efficacy of a One-Piece Aberration Neutral Hydrophobic Acrylic Toric Intraocular Lens
Phillip J Buckhurst,1 George Lau,2 Jon I Williams,2 Mark Packer3 1School of Health Professions, University of Plymouth, Plymouth, UK; 2Bausch and Lomb Surgical, Bausch and Lomb Bridgewater, New Jersey, NJ, USA; 3Mark Packer Consulting, Boulder, CO ...
Buckhurst PJ +3 more
doaj
Correction of astigmatism with toric intraocular lenses [PDF]
The purpose of this article is to explain how astigmatism can be eliminated during cataract surgery by using toric intraocular lenses (IOLs). The toric IOL calculation is analysed as well as the various types of toric IOLs.
Mallias, Ioannis +2 more
core +2 more sources
Surgically induced astigmatism in the scleral fixated ‘Carlevale’ IOL technique
Abstract Purpose To evaluate the surgically induced astigmatism over a 6‐month follow‐up period in patients who underwent scleral IOL fixation using an acrylic single‐piece IOL with special haptics designed for sutureless scleral fixation. Methods We conducted a prospective longitudinal study at a single site with a single surgeon. We included patients
Markus Schranz +5 more
wiley +1 more source
Abstract Background To evaluate repeatability and agreement in measurements of total corneal astigmatism (TCA) in keratoconic eyes, using four optical coherence tomography (OCT)‐based devices: Anterion, Casia SS‐1000, IOLMaster 700, and MS‐39. Methods Three consecutive measurements were taken with each device in 136 eyes. TCA values were converted into
Yue Feng +3 more
wiley +1 more source
Die Acrysof toric IOL: Astigmatismuskorrektur leicht gemacht
22.
Gerl, R, Gerl, M
openaire +2 more sources
Abstract Background To compare results from different corneal astigmatism measurement instruments; to reconstruct corneal astigmatism from the postimplantation spectacle refraction and toric intraocular lens (IOL) power; and to derive models for mapping measured corneal astigmatism to reconstructed corneal astigmatism.
Achim Langenbucher +7 more
wiley +1 more source
Post cataract surgery refractive surprise due to intraocular lens mislabeling
Key Clinical Message If an intraocular lens (IOL) is incorrectly labeled, problems can arise for surgeons and patients. Precise biometry is important to accurately determine the IOL power and prevent the implantation of the wrong IOL. Labeling and verifying IOLs with accuracy is crucial to ensuring the best possible results of cataract surgery ...
Saeed Shokoohi Rad +4 more
wiley +1 more source
Kjell G Gundersen,1 Richard Potvin21IFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Akron, NY, USAPurpose: To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs) using ...
Gundersen KG, Potvin R
doaj