Results 41 to 50 of about 35,565 (292)

Noncontacting transducer measures shaft torque [PDF]

open access: yes, 1966
Transducer for measuring the output torque of a rotating shaft uses a magnetically permeable sleeve fitted over a section of the shaft which deflects axially in direct proportion to the output torque. A corresponding change in reluctance occurs in pickup

core   +1 more source

Neurovascular Contacts in the Pathophysiology of Neuralgic Amyotrophy: An Observational Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Neuralgic amyotrophy (NA) is a prevalent, monophasic, multifocal immune‐mediated neuropathy. A distinctive characteristic of the disease is the occurrence of nerve or fascicle constrictions and torsions (NA‐associated focal nerve lesions, NAFL). The pathophysiology underlying this phenomenon remains to be fully elucidated.
Johannes Fabian Holle   +4 more
wiley   +1 more source

Evaluation of Axial Preload in Different-Frequency Smart Bolts by Laser Ultrasound

open access: yesSensors, 2022
We report here on a laser ultrasonic system to indirectly evaluate the preload force of different-frequency piezoelectric bolts. This newly developed system enables us to achieve the goal of non-contact excitation and synchronously collects the laser ...
Guanpin Ren   +5 more
doaj   +1 more source

Transducer measures force in vacuum environment [PDF]

open access: yes, 1966
Transducer assembly measures force in a vacuum environment. The assembly consist of a standard capacitance probe and a torque beam. This transducer can be used in high-pressure as well as in low-pressure environments for static and dynamic force ...
Glenn, D. C.
core   +1 more source

Fault Detection of Gearbox from Inverter Signals Using Advanced Signal Processing Techniques [PDF]

open access: yes, 2012
The gear faults are time-localized transient events so time-frequency analysis techniques (such as the Short-Time Fourier Transform, Wavelet Transform, motor current signature analysis) are widely used to deal with non-stationary and nonlinear signals ...
Ball, Andrew   +3 more
core   +1 more source

A Data Driven Review of In Vitro Electrical and Mechanical Stimulation for Post‐Acute Phase Wound Healing

open access: yesAdvanced Healthcare Materials, EarlyView.
This review examines how in vitro electrical and mechanical stimulation modulates wound healing in fibroblasts and keratinocytes. Analyzing over 560 experimental data points, we relate stimulation parameters to proliferation and migration outcomes, evaluate platform designs, and highlight the need for multi‐parameter optimization to advance targeted ...
Matthew K. Burgess   +3 more
wiley   +1 more source

Architectural and Mechanical Changes after Five Weeks of Intermittent Static Stretch Training on the Medial Gastrocnemius Muscle of Active Adults

open access: yesSports, 2023
We investigated the effects of intermittent long-term stretch training (5 weeks) on the architectural and mechanical properties of the muscle–tendon unit (MTU) in healthy humans.
Morgan Lévenéz   +6 more
doaj   +1 more source

A computer controlled pendulum with position readout

open access: yes, 2009
We have designed, built and operated a physical pendulum which allows one to demonstrate experimentally the behaviour of the pendulum under any equation of motion for such a device for any initial conditions.
Gasenzer, T.   +4 more
core   +1 more source

Rapid Fabrication of Self‐Propelled and Steerable Magnetic Microcatheters for Precision Medicine

open access: yesAdvanced Materials, EarlyView.
A rapid Joule heating fabrication method for the production of self‐propelling, adaptive microcatheters, with tunable stiffness and integrated microfluidic channels is presented. Demonstrated through three microrobotic designs, including a steerable guiding catheter, an untethered wave‐crawling TubeBot, and a distal‐end propelled microcatheter, it was ...
Zhi Chen   +5 more
wiley   +1 more source

Study of a 2 kN·m Torque Transducer Tested at GUM and PTB, Including Creep Behaviour

open access: yesMeasurement Science Review
This article presents a study carried out on a 2 kN·m torque transducer at the Central Office of Measures (GUM) and the Physikalisch-Technische Bundesanstalt (PTB).
Fidelus Janusz D.   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy