Results 11 to 20 of about 21,015 (221)

On the Performance Optimization of Two-Level Three-Phase Grid-Feeding Voltage-Source Inverters

open access: yesEnergies, 2018
The performance optimization of the two-level, three-phase, grid-feeding, voltage-source inverter (VSI) is studied in this paper, which adopts an online adaptive switching frequency algorithm (OASF). A new degree of freedom has been added to the employed
Issam A. Smadi   +2 more
doaj   +1 more source

An Evolutionary Annealing–Simplex Method for Inductance Value Selection for LCL Filters

open access: yesEnergies, 2023
Grid-connected voltage-source inverters (VSIs) have evolved over the past years for the interconnection of renewable energy sources with the grid to satisfy the increased electrical load demand and utilize clean carbon-free energy. However, VSIs suffer a
Xingyu Yang   +3 more
doaj   +1 more source

Bi-Level damped double-tuned harmonic passive filters design: Multi-criteria decision-making analysis

open access: yesAin Shams Engineering Journal, 2023
Harmonic distortion levels in current power systems have increased due to technical advancements in industrial and renewable energy applications. So far, passive power filters have been widely employed to minimize harmonics and lessen their adverse ...
Ahmed M. Zobaa   +2 more
doaj   +1 more source

Mitigation of harmonics for five level multilevel inverter with fuzzy logic controller

open access: yesElectrical engineering & Electromechanics, 2023
Introduction. The advantages of a high-power quality waveform and a high voltage capability of multilevel inverters have made them increasingly popular in recent years.
M. S. Sujatha   +3 more
doaj   +1 more source

Power Demand and Total Harmonic Distortion Analysis for an EV Charging Station Concept Utilizing a Battery Energy Storage System

open access: yesJournal of Electrical Engineering and Technology, 2013
To verify the effectiveness of the proposed system, the charges in power demand are analyzed for an AC and DC distribution system for the existing V2G concept and electric vehicle charging stations connected to a Battery Energy Storage System. In addition, since many powerconverter-based chargers are operated simultaneously in an EV charging station ...
Kisuk Kim   +5 more
openaire   +2 more sources

Disturbance Frequency 9 – 150 kHz Characteristics towards Total Demand Distortion on On-Grid Solar Panel System in the Electrical System of Kuningan Gas Station

open access: yesIOP Conference Series: Earth and Environmental Science, 2019
AbstractTo use solar energy into electricity, a solar panel system is needed which of course uses solar panels. As we know, a solar panel system has quite a lot of non-linear equipment, for example is an inverter. The use of this inverter will affect the power quality of the output of solar panels, one of which is disturbance. At a frequency range of 9
R P Purnamaputra, B Sudiarto
openaire   +1 more source

Harmonic Effects Due to the High Penetration of Photovoltaic Generation into a Distribution System

open access: yesEnergies, 2021
The growth in global electricity demand has expanded the search for new energy resources. Renewable sources such as photovoltaic (PV) systems have proven to be major alternatives.
Jorge Luiz Moreira Pereira   +3 more
doaj   +1 more source

Demand Side Management Effects on Substation Transformer Capacity Limits

open access: yesApplied Sciences, 2019
In high penetrations, demand side management (DMS) applications augment a substation power transformer’s load profile, which can ultimately affect the unit’s capacity limits. Energy storage (ES) applications reduce the evening peaking demand,
Kerry D. McBee   +2 more
doaj   +1 more source

Hidden Harmonic Asymmetry in a Balanced Three-Phase Building: Evidence from Field Measurements

open access: yesApplied Sciences
The increasing penetration of power electronic devices and distributed generation is significantly altering power quality conditions in low-voltage systems. While power quality assessment is commonly based on RMS currents, voltage quality indicators, and
Franjo Pranjić, Peter Virtič
doaj   +1 more source

Non-Intrusive Identification of Load Patterns in Smart Homes Using Percentage Total Harmonic Distortion

open access: yesEnergies, 2020
Demand Response (DR) plays a vital role in a smart grid, helping consumers plan their usage patterns and optimize electricity consumption and also reduce harmonic pollution in a distribution grid without compromising on their needs.
Hari Prasad Devarapalli   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy