A NEW STRUCTURE OF FIVE-LEVEL DIODE CLAMPED INVERTER WITH REDUCING ITS ELEMENTS
At the high power switching circuit's applications, when the harmonic distortion is harmful, a multi-level diode clamped inverter is useful, especially when reduced total harmonic distortion and high power are desired.
Othman M. Anssari
doaj +1 more source
Demand Response (DR) plays a vital role in a smart grid, helping consumers plan their usage patterns and optimize electricity consumption and also reduce harmonic pollution in a distribution grid without compromising on their needs.
Hari Prasad Devarapalli +2 more
semanticscholar +1 more source
Mitigation of load side harmonic distortion in standalone photovoltaic based microgrid [PDF]
Photovoltaic (PV) system as one part of distributed energy resources is becoming an alternative for low and medium distribution network of microgrid. By the reason of a wide implementation of power electronic and non-linear loads, harmonics distortion is
Aljwary Adel +3 more
doaj +1 more source
Observatory case study on total harmonic distortion in current at laboratory and office building
This paper discusses the level of harmonic distortion in current power distribution system for laboratory and office building. These two places often house a significant number of equipment such as computers, air conditioners, etc which are significant ...
M. Z. Mohd Radzi, M. Azizan, B. Ismail
semanticscholar +1 more source
Mathematical design of a new fourth-order harmonic passive filter is presented and its optimal strategy is proposed with regards to various design scenarios. The considered objective function is total demand distortion minimization of the supply current.
Nehad M. Khattab +6 more
doaj +1 more source
Utilization of an ANFIS-STSM Algorithm to Minimize Total Harmonic Distortion
Recently applications of second order super-twisting sliding mode (STSM) algorithm become more convenient in control of AC machines. The conventional technique, the capability of creating a high value of current or voltage.
H. Benbouhenni
semanticscholar +1 more source
Standards of distorted signal for calibration of total harmonic distortion meters [PDF]
In this article a survey and evaluation of some progressive approaches to the standards of non-linear distortion is reported. Some types of standards of signals with the known total harmonic distortion used for calibration of distortion measuring instruments are proposed.
openaire +3 more sources
The use of photovoltaic (PV) systems has increased in recent years due to the high demand for clean energy sources. PV systems can utilize abundant and free energy from the sun, which is a substantial advantage.
Liqaa Alhafadhi, J. Teh
semanticscholar +1 more source
This paper deals with the use of least mean squares (LMS, NLMS) and recursive least squares (RLS) algorithms for total harmonic distortion (THD) reduction using shunt active power filter (SAPF) control.
R. Martínek +4 more
semanticscholar +1 more source
Real‐time estimating harmonic distortion levels near the Point of Interconnections of grid‐connected inverter‐based resources (IBRs) is critical for maintaining the operational reliability and security of the power grid, particularly during transients ...
Reza Saeed Kandezy +3 more
doaj +1 more source