Results 31 to 40 of about 77,910 (281)

Encoding of Tactile Stimuli by Mechanoreceptors and Interneurons of the Medicinal Leech [PDF]

open access: yes, 2016
For many animals processing of tactile information is a crucial task in behavioral contexts like exploration, foraging, and stimulus avoidance. The leech, having infrequent access to food, developed an energy efficient reaction to tactile stimuli ...
Fathiazar, Elham   +3 more
core   +4 more sources

Threshold Potential Simulation on Grounding System using CYMGround Substation Program

open access: yesJurnal Elkomika
Excessive fault current on a poor grounding system can cause several symptoms such as the appearance of touch and step voltage and affect the grounding resistance value.
AYU FITRIANI   +5 more
doaj   +1 more source

Control the cost, touch and step voltages of the grounding grids design

open access: yesIET Science, Measurement & Technology, 2016
In this study, an evolutionary strategy is presented to get the optimal grounding grid design to minimise the design cost, the touch and step voltages of the grounding grid to ensure the economical constraint as well as the safety conditions. The proposed technique is used for one and two‐layer soil.
Sherif S.M. Ghoneim, Ibrahim B.M. Taha
openaire   +1 more source

EVALUATION SUBSTATION PROTECTION SYSTEM FROM LIGHTNING STRIKES AT 150KV JATIGEDE SUBSTATION

open access: yesProtek: Jurnal Ilmiah Teknik Elektro
Grounding serves a crucial role in the field lightning protection, electric power, and electric power communications networks. The grounding system's purpose is to guide the flow of electrical charges to the ground mass as rapidly as feasible.
Taryo Taryo   +2 more
doaj   +1 more source

Grid Grounding Calculations for a 132-KV Substation Using Soil Backfilling

open access: yesIEEE Access, 2019
Safe and reliable grid design is complicated by the compact design of gas insulated substations (GIS). This paper discusses the complete grounding design procedure for a 132-KV substation in the city of Al Kharj based on the IEEE-80 specifications and ...
Saeed Alyami
doaj   +1 more source

Power quality and electromagnetic compatibility: special report, session 2 [PDF]

open access: yes, 2015
The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in ...
Desmet, Jan   +2 more
core   +1 more source

Tumor‐stromal crosstalk and macrophage enrichment are associated with chemotherapy response in bladder cancer

open access: yesFEBS Open Bio, EarlyView.
Chemoresistance in bladder cancer: Macrophage recruitment associated with CXCL1, CXCL5 and CXCL8 expression is characteristic of Gemcitabine/Cisplatin (Gem/Cis) Non‐Responder tumors (right side) while Responder tumors did not show substantial tumor‐stromal crosstalk (left side). All biological icons are attributed to Bioicons: carcinoma, cancerous‐cell‐
Sophie Leypold   +11 more
wiley   +1 more source

Rancang Bangun Model Pengujian Tegangan Langkah Pada Titik Pentanahan Metode Rod Dan Metode Mesh [PDF]

open access: yes, 2011
Step voltage is the voltage on both legs affected by living beings (human and animal) due to be in electrified areas. This current flow can occur due to lightning, the voltage is leaking into the ground, under-voltage wires disconnected and touch the ...
Isdawimah, I. (Isdawimah)   +3 more
core  

Polarization‐resolved femtosecond Vis/IR spectroscopy tailored for resolving weak signals in biological samples using minimal sample volume

open access: yesFEBS Open Bio, EarlyView.
Unique biological samples, such as site‐specific mutant proteins, are available only in limited quantities. Here, we present a polarization‐resolved transient infrared spectroscopy setup with referencing to improve signal‐to‐noise tailored towards tracing small signals. We provide an overview of characterizing the excitation conditions for polarization‐
Clark Zahn, Karsten Heyne
wiley   +1 more source

Effectiveness of 2-Layered grounding grids in high voltage GIS substations and new design considerations using FEM

open access: yesDyna
With the rising demand for electricity and the expansion of power generation facilities, grounding systems have become critical for ensuring human safety and equipment protection.
Asaad Shemshadi   +4 more
doaj   +1 more source