Results 21 to 30 of about 248 (107)
A novel approach to touch voltage risk assessment for gas pipelines in shared transmission corridors
Touch voltages are more likely to appear on long‐distance pipelines that lie in shared corridors with transmission lines. The touch voltage level varies with soil resistivity and can become hazardous while maintenance is being undertaken, necessitating ...
Keith Man‐Kei Chan +2 more
doaj +1 more source
Coral Stone Installation On the Substation Grounding System In Limestone
The step voltage and touch voltage exceed the maximum limit due to overcurrent to the ground flowing in the equipment grounding area which is dangerous for the equipment and people in the vicinity.
I Gusti Ngurah Janardana +1 more
doaj
A New Method of Grounding Grid Design
In order to equalize the electric potential distribution of the grounding grid surface, and improve the safety level of the grounding grid, method for optimal arrangement of conducts in the grounding grid is proposed in this paper.
Feng Zhen-Bao +3 more
doaj +1 more source
Grid Grounding Calculations for a 132-KV Substation Using Soil Backfilling
Safe and reliable grid design is complicated by the compact design of gas insulated substations (GIS). This paper discusses the complete grounding design procedure for a 132-KV substation in the city of Al Kharj based on the IEEE-80 specifications and ...
Saeed Alyami
doaj +1 more source
A Force–Voltage Responsivity Stabilization Method for Piezoelectric Touch Panels in the Internet of Things [PDF]
Piezoelectric force touch panels are extensively utilized as human-machine interfaces for 3-dimensional touch sensing in internet of things (IoT) applications. However, the unstable force voltage responsivity issue induced by different touch orientations limits the successful use of piezoelectric touch panels.
Shuo Gao +3 more
openaire +2 more sources
In this paper, we propose a bidirectional gate driver on array (GOA) circuit design based on indium gallium zinc oxide (IGZO) thin-film transistor (TFT) to support time-division driving method (TDDM) for in-cell touch displays.
Liufei Zhou +6 more
doaj +1 more source
The resistive ground fault of PWM voltage inverter in the EV charging station
During the direct touch of the inverter output voltage or with the ungrounded shield of the cable connecting the inverter to the motor or other type of load, the nonsinusoidal ground currents with a basic harmonic frequency between 1.5 and 16 kHz, flow ...
Marta Zurek-Mortka, Jerzy R. Szymanski
doaj +1 more source
An EMTP Extension for Computing Earthing System Transient Step and Touch Voltages
This paper presents a novel technique for computing dangerous voltages due to lightning transients imposed on earthing system, which is based on the use of the well-known ATP-EMTP software package. Earth surface transient potential distributions, as well as step and touch voltages computations, are performed through extending the widely used EMTP ...
Vujević, Slavko, Sarajčev, Petar
openaire +6 more sources
Threshold Potential Simulation on Grounding System using CYMGround Substation Program
Excessive fault current on a poor grounding system can cause several symptoms such as the appearance of touch and step voltage and affect the grounding resistance value.
AYU FITRIANI +5 more
doaj +1 more source
When a fault occurs in a power transmission system, voltages that are dangerous to people may occur. The aim of this work is to present the following method of protection: the use of protective foil installed at the appropriate depth around the ...
Marko Jesenik +3 more