Exploiting Inter- and Intra-Memory Asymmetries for Data Mapping in Hybrid Tiered-Memories
Modern computing systems are embracing hybrid memory comprising of DRAM and non-volatile memory (NVM) to combine the best properties of both memory technologies, achieving low latency, high reliability, and high density.
Antognetti P. +32 more
core +1 more source
Higher Network Activity Induced by Tactile Compared to Electrical Stimulation of Leech Mechanoreceptors [PDF]
The tiny ensemble of neurons in the leech ganglion can discriminate the locations of touch stimuli on the skin as precisely as a human fingertip. The leech uses this ability to locally bend the body-wall away from the stimulus. It is assumed that a three-
Fathiazar, Elham +2 more
core +3 more sources
Coral Stone Installation On the Substation Grounding System In Limestone
The step voltage and touch voltage exceed the maximum limit due to overcurrent to the ground flowing in the equipment grounding area which is dangerous for the equipment and people in the vicinity.
I Gusti Ngurah Janardana +1 more
doaj
Grid Grounding Calculations for a 132-KV Substation Using Soil Backfilling
Safe and reliable grid design is complicated by the compact design of gas insulated substations (GIS). This paper discusses the complete grounding design procedure for a 132-KV substation in the city of Al Kharj based on the IEEE-80 specifications and ...
Saeed Alyami
doaj +1 more source
POSFET tactile sensing arrays using CMOS technology [PDF]
This work presents fabrication and evaluation of novel POSFET (Piezoelectric Oxide Semiconductor Field Effect Transistor) devices based tactile sensing chip.
Adami, Andrea +3 more
core +1 more source
In this paper, we propose a bidirectional gate driver on array (GOA) circuit design based on indium gallium zinc oxide (IGZO) thin-film transistor (TFT) to support time-division driving method (TDDM) for in-cell touch displays.
Liufei Zhou +6 more
doaj +1 more source
The resistive ground fault of PWM voltage inverter in the EV charging station
During the direct touch of the inverter output voltage or with the ungrounded shield of the cable connecting the inverter to the motor or other type of load, the nonsinusoidal ground currents with a basic harmonic frequency between 1.5 and 16 kHz, flow ...
Marta Zurek-Mortka, Jerzy R. Szymanski
doaj +1 more source
Threshold Potential Simulation on Grounding System using CYMGround Substation Program
Excessive fault current on a poor grounding system can cause several symptoms such as the appearance of touch and step voltage and affect the grounding resistance value.
AYU FITRIANI +5 more
doaj +1 more source
Prevalence and Trajectory of Household Material Hardship Among Children With Advanced Cancer
ABSTRACT Background/Objectives Families of children with advanced cancer living in poverty experience inferior outcomes including poor parent mental health and worse child quality of life. Household material hardship (HMH: food, housing, transportation, and/or utility insecurity) is a modifiable poverty exposure—and potential intervention target—that ...
Sarah Wright +13 more
wiley +1 more source
Влияние частоты измерительного тока при измерении напряжения прикосновения на электрооборудовании энергообъектов с использованием измерительного комплекса "КДЗ−1У" [PDF]
Рассмотрено влияние частоты измерительного тока при измерении напряжения прикосновения. Показана зависимость погрешности измерений напряжения прикосновения от частоты измерительного тока.
Воронина, Зоя Анатольевна +6 more
core