Purpose. The purpose of the work is to analyze the modern methods of control and determine the most effective ones for monitoring the state of grounding of existing energy objects in operation. Methodology.
D. G. Koliushko, S. S. Rudenko
doaj +1 more source
The Effect of Soil Type on Touch Voltage and Step Voltage in the Grid Grounding System
The grounding system is one of the security systems in substations to channel excess voltage caused by lightning strikes that occur at substations, as well as electrical equipment. To design a grounding system, there are several factors that must be considered, including the type of soil, the configuration of the grounding system, the resistivity of ...
Ayu Fitriani +2 more
openaire +2 more sources
Purpose. Experimental substantiation of the possibility of using the calculation procedure of normalized parameters grounding devices on the basis of a three-layer model soil. Methodology.
D. G. Koliushko, S. S. Rudenko
doaj +1 more source
Discussion on design standard of low-voltage IT grounding system in underground mine
The paper introduced principle of grounding fault of low-voltage IT grounding system in underground mine for the first time, and pointed out it is meaningless of a requirement in GB 50070-2009 Design Code for Electric Power in Mine that fault current ...
GUAN Hengzhu
doaj +1 more source
MSSB to Prevent Cable Termination Faults for Long High Voltage Underground Cable Lines
Cable termination fault is one of the most important problems for high voltage underground cable lines (HVUCL). Harmonic current (HC) and the sheath current (SC) are causes of cable termination faults of HVUCL.
Bahadir Akbal
doaj +1 more source
Piezoelectric vs. Capacitive Based Force Sensing in Capacitive Touch Panels
High sensitivity force sensing is a desirable function of capacitance touch screen panels. In this paper, we report on a dynamic force detection technique by utilizing piezoelectric materials.
Shuo Gao, Victor Arcos, Arokia Nathan
doaj +1 more source
Analysis of Electrical Safety Conditions Taking into Account Soil Conductivity Determined on the Basis of Fuzzy Logic [PDF]
The goal of this work is to prove a possibility of determining soil parameters that influence its conductivity being the basis of grounding, step voltage and touch voltage calculation.
Manusov V.Z., Zaytseva N.M.
doaj
Touch sensors based on planar liquid crystal-gated-organic field-effect transistors
We report a tactile touch sensor based on a planar liquid crystal-gated-organic field-effect transistor (LC-g-OFET) structure. The LC-g-OFET touch sensors were fabricated by forming the 10 μm thick LC layer (4-cyano-4′-pentylbiphenyl - 5CB) on top of the
Jooyeok Seo +9 more
doaj +1 more source
In this paper, comparative assessments of four earthing grid system configurations (the triangular shape, the rectangular shape, the T-shape and the L-shape) are performed with the aim of determining the best earthing grid configuration in terms of ...
T.R. Ayodele +2 more
doaj +1 more source
Results of research on distribution of electric potentials on the earth surface in the territory with a grounding conductor are analyzed. It is shown that potential over the center of a square grounding conductor can be higher than that over the ...
I.V. Nizhevskyi +2 more
doaj