Results 11 to 20 of about 1,529,744 (164)

Implantation of trabecular micro-bypass stent using a novel “landing strip” technique [PDF]

open access: yesInternational Journal of Ophthalmology, 2017
AIM: To describe a novel technique of creating a landing strip within the trabecular meshwork to guide trabecular micro-bypass stent (iStent) implantation in patients who underwent phacoemulsification.
Cindy X. Zheng   +5 more
doaj   +6 more sources

Outcomes of combined trabecular micro-bypass and phacoemulsification in a predominantly Hispanic patient population

open access: yesClinical Ophthalmology, 2016
Mark J Gallardo,1,2 Richard A Supnet,1 Jane Ellen Giamporcaro,3 Dana M Hornbeak3 1El Paso Eye Surgeons, PA, El Paso, 2Department of Ophthalmology, University of Texas Health Science Center at San Antonio, San Antonio, TX, 3Division of Clinical Research ...
Gallardo MJ   +3 more
doaj   +9 more sources

iStent trabecular micro-bypass stent for open-angle glaucoma

open access: yesClinical Ophthalmology, 2014
Kim Le, Hady Saheb Department of Ophthalmology, McGill University, Montreal, QC, Canada Abstract: Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other
Le K, Saheb H
doaj   +7 more sources

Retrospective analysis of indications and outcomes of trabecular micro-bypass stent implantation in Indian eyes [PDF]

open access: yesIndian Journal of Ophthalmology
Purpose: To analyze the patient characteristics, initial outcomes, and complications associated with iStent implantation in Indian eyes. Methods: This retrospective case series comprised subjects who underwent iStent, iStent inject, or iStent inject W ...
Amit Pandey   +5 more
doaj   +3 more sources

Efficacy and Safety of Kahook Dual Blade Goniotomy and Trabecular Micro-Bypass Stent in Combination with Cataract Extraction [PDF]

open access: yesBiomimetics
In recent years, rapid advancements in glaucoma research have led to the development of more effective treatments of this chronic and irreversible condition. Of these, Kahook Blade Dual (KDB) goniotomy and second-generation trabecular micro-bypass stent (
Kevin Y. Wu   +3 more
doaj   +4 more sources

A Brazilian cost-utility analysis of trabecular micro-bypass with iStent inject® for the treatment of open-angle glaucoma [PDF]

open access: yesRevista Brasileira de Oftalmologia, 2022
Purpose To evaluate the cost-utility of the iStent inject® for the treatment of mild-to-moderate open-angle glaucoma (OAG) within the Brazilian Unified Health System (SUS). Methods A Markov model was developed, in which the effectiveness outcome measure
Ricardo Augusto Paletta Guedes   +5 more
doaj   +2 more sources

A review of the iStent® trabecular micro-bypass stent: safety and efficacy

open access: yesClinical Ophthalmology, 2015
There is a significant demand for procedures that can effectively treat glaucoma with low risk and good visual outcomes. To fill this void, procedures termed "minimally invasive glaucoma surgery", are gaining in popularity. This review will focus on the safety and efficacy of one such minimally invasive glaucoma surgery procedure, the trabecular micro ...
Wellik, Sarah R, Dale, Elizabeth A
core   +6 more sources

Trabecular Meshwork Thickness Measured by Swept-Source AS-OCT as a Predictor of Surgical Outcomes After Trabecular Micro-Bypass Stent Implantation [PDF]

open access: yesJournal of Clinical Medicine
Background: Although minimally invasive glaucoma surgery (MIGS), including trabecular micro-bypass stent implantation, is safe, its surgical outcomes remain variable, with limited reliable success predictors. We evaluated whether preoperative trabecular meshwork (TM) thickness is associated with surgical outcomes after iStent inject® W implantation ...
Jiwoong Lee, Ji Eun Lee, Sangwoo Moon
exaly   +4 more sources

Effect of iStent Trabecular Micro-Bypass device on outflow system morphology

open access: yesModeling and Artificial Intelligence in Ophthalmology, 2020
Purpose: Rigorous clinical testing has established that Schlemm’s canal cross-sectional area (SC-CSA) is reduced in glaucomatous eyes. However, to date, it is unclear whether trabecular bypass procedures impact the morphology of the proximal aqueous outflow tract, or if the introduction of a local region of low outflow resistance adversely affects SC ...
Hess, Nicholas   +12 more
openaire   +3 more sources

Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series [PDF]

open access: yesJournal of Ophthalmology, 2017
Purpose. To evaluate efficacy and safety of a trabecular micro-bypass stent system when used as the sole procedure in Japanese patients with medically uncontrolled primary open-angle glaucoma (POAG). Design. Prospective nonrandomized interventional pilot
Daisuke Shiba   +5 more
doaj   +2 more sources

Home - About - Disclaimer - Privacy