Results 141 to 150 of about 413 (183)
Some of the next articles are maybe not open access.
Dimensioning DC Traction Substations with Realistic Traffic Scenarios
2017 IEEE Vehicle Power and Propulsion Conference (VPPC), 2017The study of energy consumption is fundamental for railway systems in general and for DC electrified railway systems in particular. It plays an important role in order to design a proper dimensioning of traction Substations (SSs). DC electrical multi-train simulators allow studying a lot of electrical variables that are related to energy consumption ...
Roch Dupré, David +4 more
openaire +3 more sources
Analysis of the Energy Characteristics of the Traction Substation Rectifier
2021 IEEE 2nd KhPI Week on Advanced Technology (KhPIWeek), 2021The analysis of the electromagnetic processes of a rectifier unit with a controlled pulse-width modulation with a booster rectifier is carried out. An expression for the power factor of a rectifier unit is obtained by an integral method for determining reactive power. It is shown that the adjustable pulse width modulation parameter has little effect on
Yakov Shcherback +2 more
openaire +1 more source
Rectifiers for railway-traction substations
IEE Journal on Electric Power Applications, 1979This is a general review of the present state of development of silicon rectifier equipment for the supply of d.c. for railway traction. Current general practice is described and reference is made to the latest developments, including compensators for paralleling double-bridge rectifiers, and capsule diodes.
openaire +1 more source
Application of TSC in reactive compensation in traction substations
Proceedings 2000 International Workshop on Autonomous Decentralized System (Cat. No.00EX449), 2002This paper presents the parameter design of components of thyristor switched capacitor (TSC) compensation with step-down transformer under the restriction of reactive power balance, and also mentions the pattern of TSC cooperated with fixed capacitor banks. The design and simulation is fully automated by the visual CVI.
null Zhang Li, null Li Qun-Zhan
openaire +1 more source
Research on electromagnetic radiation of Xijiang traction substation
2018 IEEE International Symposium on Electromagnetic Compatibility and 2018 IEEE Asia-Pacific Symposium on Electromagnetic Compatibility (EMC/APEMC), 2018Electromagnetic radiation of Xijiang traction substation is studied by metrical, analyses and scientific research, and field strength of power frequency, radio interference and distance attenuation characteristic are acquired in this paper. By scanning frequency in peak detection mode, electrical field and magnetic field strength covering band of 9kHz ...
Xiaohu Zeng +8 more
openaire +1 more source
Probability Distribution for the Feeder Current of Traction Substation
2009 Asia-Pacific Power and Energy Engineering Conference, 2009Probability density function for feeder current of traction substation is fitted by using beta function through the theory of stochastic process and method of numerical analysis, and the distribution characteristic of feeder current is generalized and analyzed based on a great deal recorded feeder current data.
Li-Yan Zhang +2 more
openaire +1 more source
Heavy-duty rectifiers and their application to traction substations
Journal of the Institution of Electrical Engineers, 1931As a result of the special problems associated with the supply of direct current to traction systems, as distinct from lighting and power systems, automatic substation technique has advanced in two widely diverging directions. Whereas modern substation practice in America is characterized by practice favours the adoption of mercury-arc rectifiers.
J.W. Rissik, H. Rissik
openaire +1 more source
Dynamic reactive power compensation in traction substations
International Conference on Road and Rail Infrastructure, 2018The converter for dynamic reactive power compensation KONTRAC PN225AC is produced by Končar – Electronics and Informatics, Inc. and is built in traction substations 25 kV, 50 Hz. The rated power of the converter is 225 kvar and a response of the converter to step change of rated reactive power is less than few periods of the supply voltage main ...
Krušelj, Dubravko +2 more
openaire +2 more sources
Influence of grounding wire configuration of traction substation
2019 11th Asia-Pacific International Conference on Lightning (APL), 2019In this paper, the influence of grounding wire configuration of traction substation on observed transient overvoltage at some electric machines, those are diode rectifier, series reactor and so on, is experimentally measured. According to our previous experiences, a diode rectifier is the weakness against lightning and making the transient voltage ...
Tomohiro Owaku +5 more
openaire +1 more source
Cooperation of AC Traction Substations
IECON 2023- 49th Annual Conference of the IEEE Industrial Electronics Society, 2023Milos Straka +3 more
openaire +1 more source

