Results 91 to 100 of about 499,140 (140)
Therapeutic Balloon‐Assisted Enteroscopy: Recent Advances in the Management of Small Bowel Diseases
DEN Open, Volume 7, Issue 1, April 2027.ABSTRACT
Balloon‐assisted enteroscopy (BAE) has substantially advanced small bowel disease management. This review summarizes recent therapeutic BAE advances, focusing on three major indications: small bowel vascular lesions, hereditary polyposis syndromes, and Crohn's disease (CD).Manabu Nagayama, Tsubasa Kinoshita, Hiroyuki Kawaguchi, Toshihiro Fujinuma, Sawako Fujikura, Hiroki Hayashi, Tomoko Tamaru, Hirotsugu Sakamoto, Tomonori Yano +8 morewiley +1 more sourceOutcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves
Journal of the American Heart Association: Cardiovascular and Cerebrovascular DiseaseBackground The impact of aortic valve morphology on outcomes after transcatheter aortic valve replacement in patients with mixed aortic valve disease, characterized by the coexistence of aortic stenosis and regurgitation, remains poorly defined.Yu Tang, Yuan Feng, Xue‐Chen Qiao, Meng‐Yun Yan, Yue Yin, Wei‐Ya Li, Tian‐Yuan Xiong, Yi‐Ming Li, Jun‐Li Li, Lin Bai, Xin Wei, Yuan‐Wei Xiang Ou, Zhong‐Kai Zhu, Yi‐Jun Yao, Qiao Li, Yi‐Jian Li, Fei Chen, Jia‐Fu Wei, Yong Peng, Zhen‐Gang Zhao, Mao Chen +20 moredoaj +1 more sourceImaging techniques in transcatheter aortic valve replacement
, 2013 Robert A Quaife, Jennifer Dorosz, John C Messenger, Ernesto E Salcedo Division of Cardiology, University of Colorado, Aurora, CO, USA Abstract: Calcific aortic stenosis is now understood as a complex valvular degenerative process sharing many risk ...Quaife RA, Salcedo EE, Dorosz J, Messenger JC +3 morecore Standardized Reporting of Cardiac Magnetic Resonance Examinations in Children With Cardiac Diseases and Adults With Congenital Heart Disease: A Scientific Statement From the Association for European Pediatric and Congenital Cardiology (AEPC) and the International Society for Magnetic Resonance in Medicine (ISMRM)
Journal of Magnetic Resonance Imaging, EarlyView.Francesca Raimondi, Inga Voges, Lamia Ait‐Ali, Sonya Babu‐Narayan, Rene Botnar, Barbara Burkhardt, Adrienne Campbell‐Washburn, Dominik Daniel Gabbert, Georg Hansmann, Willem A. Helbing, Hasan Hosan, Sylvia Krupickova, Heiner Latus, Duarte Martins, Colin McMahon, Christian Meierhofer, Vivek Muthurangu, Tiina Ojala, Pim van Ooij, Claudia Prieto, Milan Prsa, Kuberan Pushparajah, José F. Rodríguez Palomares, Samir Sarikouch, Lars Grosse‐Wortman, F. Gerald Greil, Heynric Grotenhuis +26 morewiley +1 more sourceComparison Between the Acurate Neo and the Acurate Neo 2 Transcatheter Heart Valve System: Impact of Midframe Under‐Expansion
Catheterization and Cardiovascular Interventions, Volume 108, Issue 5, Page 1784-1794, November 1, 2026.ABSTRACT Background
Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.Lisa Crusius, Thaddäus Ast, Stephan Haussig, Jean‐Honoré Steul, Felix J. Woitek, Peter Sick, Tomas Madej, Utz Kappert, Axel Linke, Norman Mangner +9 morewiley +1 more sourceSuccessful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
Catheterization and Cardiovascular Interventions, Volume 108, Issue 5, Page 1962-1964, November 1, 2026.ABSTRACT
Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are Seyed Hossein Aalaei‐Andabili, Diljon S. Chahal, Shahab Tour Savadkohi +2 morewiley +1 more sourceFeasibility and Procedural Considerations of Balloon‐Expandable TAVR in Patients With Prior Endovascular Aortic Stent Grafts
Catheterization and Cardiovascular Interventions, Volume 108, Issue 5, Page 1993-1999, November 1, 2026.ABSTRACT Objectives
To evaluate the feasibility and short‐term outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable Sapien valves in patients with prior endovascular aortic stent grafts. Methods
We conducted a single‐center, retrospective study of 23 patients with prior endovascular aortic stent grafts who underwent TAVR ...Iad Alhallak, Alexander Mills, Beau Bequeaith, Ken Chan, Akiko Tanaka, Anthony L. Estrera, Biswajit Kar, Richard Smalling, Abhijeet Dhoble +8 morewiley +1 more sourceAn Ascorbic‐Acid Containing Poly(Carbonate) Urethane With Antioxidant Bioactivity for Application in Heart Valve Scaffold Development
Journal of Biomedical Materials Research Part A, Volume 114, Issue 11, November 2026.ABSTRACT
Prosthetic heart valve development consists of several branching, innovative strategies to mediate the complex native environment that wears down valve durability. Anti‐calcification treatments are being applied to pericardial tissue, durable polymers are being developed that mitigate oxidative degradation and stress cracking, and heart valve ...Drake D. Pedersen, Keishi Kohyama, Taro Fujii, Marianna Barbuto, Sangho Ye, Sujeong Park, Flaviana Falci, Jooyoun Park, Keun Seok Seo, William Long, Antonio D'Amore, Seungil Kim, William R. Wagner +12 morewiley +1 more sourceDevelopment and evaluation of X‐ray lithophanes as test objects for interventional procedure simulation
Medical Physics, Volume 53, Issue 11, November 2026.Abstract Background
In the growing field of interventional radiology, emerging technologies implement the use of artificial intelligence (AI) to help tackle growing demands for treatment. Due to the anatomical differences in animals, volunteers offer the most realistic training and testing scenario, however safety considerations restrict rapid ...Carlo Saija, Madeleine Dietrich, Federica Facente, Wen Wei, Campbell Littlefield, Mariia Kryshchuk, Pablo Aparicio‐Villar, Nassim Boudjatit, Antonia Pontiki, Richard James Housden, Eric Sejor, Kawal Rhode, Pierre Berthet‐Rayne +12 morewiley +1 more sourceTranscaval Transcatheter Aortic Valve Replacement for Pure Aortic Regurgitation Using a Dedicated Self-Expanding Device
JACC: Case ReportsNovel dedicated devices allow transcatheter treatment of pure aortic regurgitation (AR). The JenaValve Trilogy Heart Valve System was introduced as the first dedicated and on-label AR transcatheter aortic valve replacement system, implementing a locator ...Jonathan Curio, MD, Stephan Nienaber, MD, Elmar W. Kuhn, MD, Kaveh Eghbalzadeh, MD, Wael Ahmad, MD, Arash Mehdiani, MD, Jörg Schröder, MD, Maria Isabel Körber, MD, Hendrik Wienemann, MD, Stephan Baldus, MD, Matti Adam, MD +10 moredoaj +1 more source