Results 61 to 70 of about 532,343 (297)
This study reveals how the mitochondrial protein Slm35 is regulated in Saccharomyces cerevisiae. The authors identify stress‐responsive DNA elements and two upstream open reading frames (uORFs) in the 5′ untranslated region of SLM35. One uORF restricts translation, and its mutation increases Slm35 protein levels and mitophagy.
Hernán Romo‐Casanueva +5 more
wiley +1 more source
Improvement of the evaluation method of calculation of power losses in power transformer
Purpose. The purpose of the work is to perform analytical analysis of methods for calculating power losses of a power transformer and to improve the estimation method of calculation to increase the accuracy of calculating power losses on the example of ...
O.S. Pidlisniy O.S., S.P. Lushchin
doaj +1 more source
Identification of interturn faults in power transformers by means of generalized symmetrical components analysis [PDF]
The paper deals with experimental identification of transformer internal faults, an important factor in reliability and sustainability of power supply systems. Task of identification of transformer internal faults requires increasing sensitivity of relay
Ivanchenko Daniil, Smirnov Artem
doaj +1 more source
Self-attention networks have revolutionized natural language processing and are making impressive strides in image analysis tasks such as image classification and object detection. Inspired by this success, we investigate the application of self-attention networks to 3D point cloud processing.
Zhao, H +4 more
openaire +3 more sources
Sequence determinants of RNA G‐quadruplex unfolding by Arg‐rich regions
We show that Arg‐rich peptides selectively unfold RNA G‐quadruplexes, but not RNA stem‐loops or DNA/RNA duplexes. This length‐dependent activity is inhibited by acidic residues and is conserved among SR and SR‐related proteins (SRSF1, SRSF3, SRSF9, U1‐70K, and U2AF1).
Naiduwadura Ivon Upekala De Silva +10 more
wiley +1 more source
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and result in a reduced capacity of the transformer.
Sulistiyono Sulistiyono, Haris Nur Azis
doaj +1 more source
Circuit for automatic load sharing in parallel converter modules [PDF]
A nondissipative circuit for automatic load sharing in parallel converter modules having push-pull power transistors is presented. Each transistor has a separate current-sensing transformer and an impedance-adjusting transformer in series with its ...
Nagano, S.
core +1 more source
The Ile181Asn variant of human UDP‐xylose synthase (hUXS1), associated with a short‐stature genetic syndrome, has previously been reported as inactive. Our findings demonstrate that Ile181Asn‐hUXS1 retains catalytic activity similar to the wild‐type but exhibits reduced stability, a looser oligomeric state, and an increased tendency to precipitate ...
Tuo Li +2 more
wiley +1 more source
One of the critical pieces of equipment for power transmission and distribution is the transformer. The operation of the transformers is essential for the power supply's continued stability and efficacy. With an increase in rated power, the transformer's
Kamran Dawood, Semih Tursun
doaj +1 more source
Study on harmonic metering characteristics of Rogowski coil current transformer
This paper introduces the harmonic requirements of a power system transformer and the principle of the Rogowski coil electronic current transformer, summarizes the simple and practical methods for harmonic measurement of the Rogowski coil electronic ...
Liwen Chen +7 more
doaj +1 more source