Results 11 to 20 of about 21,646 (293)
Improving the quality of 0.4 kV electricity in household appliances due to voltage regulation [PDF]
The article discusses a way to improve the quality of electricity up to 0.4 kV household appliances through voltage regulation. As an actuator, a booster transformer with two secondary windings connected in accordance with the primary winding is used ...
Karimov Raxmatillo
doaj +1 more source
The existing research on the distribution characteristics of displacement and acceleration of the transformer axial vibration under short-circuit conditions is based on ignoring the damping parameters.
Shuguo Gao +3 more
doaj +1 more source
Two Winding Transformer Equivalent Model of Three Winding Transformers for MATPOWER
MATPOWER is one of wide used authoriterative open source software of power flow calculation in the world. However, it only provides a model of the two-winding transformer thus limiting its application in power system with a three-winding transformer which is very popular in the power system.
MD MUNNA TALUKDER +3 more
openaire +2 more sources
Power transformer geometry monitoring of active parts by SFRA method [PDF]
During regular operation, power transformer windings are continuously exposed to electromechanical stresses and vibrations. Surges during lightning or short circuits may cause the weakening of the mechanical structure and the mechanical reinforcing parts
Ilić Denis +2 more
doaj +1 more source
Design and operation of a protection system for transformers with superconducting windings [PDF]
Power transformers with superconducting windings need a protection system to prevent damage to the low-loss superconducting winding by an abnormally high current.
Klundert, L.J.M. van de +2 more
core +3 more sources
Turn-to-turn fault protection technique for synchronous machines without additional voltage transformers [PDF]
This paper presents a novel protection technique for the detection of inter-turn faults in synchronous machines. It is based on the calculation of voltage in the stator windings from the usual phases and neutral voltage, typically available in ...
Gyftakis, Konstantinos N. +2 more
core +1 more source
Practical Study of Mixed-Core High Frequency Power Transformer
The design of medium- to high-frequency power electronics transformer aims not only to minimize the power loss in the windings and the core, but its heat removal features should also allow optimal use of both core and copper.
Arun Kumar Paul
doaj +1 more source
TARGET. The purpose of this work is to develop a non-contact laser control and measuring complex (LCMC) for vibration control of the level of pressing of windings and magnetic circuit of a power transformer.
V. R. Basenko +3 more
doaj +1 more source
Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults [PDF]
Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the ...
V. Behjat, A. Shams, V. Tamjidi
doaj +1 more source
Goal. Analysis of the influence of the active resistance of the primary and secondary windings of a pulse transformer on the voltage at the load capacitance based on the developed methodology for the analysis of transients caused by the discharge of the ...
A. G. Gurin, I. A. Kostiukov
doaj +1 more source