Results 21 to 30 of about 21,646 (293)
In order to analyze influence of air gaps or impurities in insulation layer on temperature rise of windings of mine-used flameproof dry-type transformer, a mine-used 1 000 kVA/10 kV dry-type transformer with continuous winding was selected as research ...
WAN Zhiqiang +3 more
doaj +1 more source
Controlling the highest temperature in the windings is the primary objective of transformer thermal design to guarantee designed transformer thermal life expectancy.
Xiang Zhang +3 more
doaj +1 more source
Investigation of Asymmetrical Modes of Three-Phase Three Leg Combined Transformer-Phase-Shifter [PDF]
On the base of previously proposed model of three-phase three leg transformer windings connection scheme for combined transformer-phase shifter was made, for which calculations and analysis of specific characteristics of different steady state asymmetric
Bosneaga V.A., Suslov V.M.
doaj
Evaluation Method for Winding Performance of Distribution Transformer
In order to ensure the safe and stable operation of a power system, the performance evaluation of transformer windings after a short-circuit test can predict whether the windings are deformed in order to provide a useful reference for the operation and ...
Chunguang Suo +5 more
doaj +1 more source
MACHINE-TRANSFORMER UNITS FOR WIND TURBINES
Background. Electric generators of wind turbines must meet the following requirements: they must be multi-pole; to have a minimum size and weight; to be non-contact, but controlled; to ensure the maximum possible output voltage when working on the power supply system. Multipole and contactless are relatively simply realized in the synchronous generator
V.I. PANCHENKO +4 more
openaire +5 more sources
Methods for determining the scattering of transformer windings individually
The total leakage reactance of the transformer with concentric cylindrical windings depends on the thickness of the coils and the gap between them.
Popov I. P.
doaj +1 more source
Non-Sinusoidal Loading Effect on Oil Immersed Power Transformers [PDF]
Transformers are usually designed for nominal frequency and sinusoidal load current. Nowadays, usage of non-linear loads such as power electronics loads has extremely increased.
Mohammed k.Edan
doaj +1 more source
Improved transient simulation of salient-pole synchronous generators with internal and ground faults in the stator winding [PDF]
An improved model for simulating the transient behavior of salient-pole synchronous generators with internal and ground faults in the stator winding is established using the multi-loop circuit method.
Bi, D.Q. +4 more
core +1 more source
The power transformer is a critical primary device in the power grid, and the verification of its winding mechanical stability is of paramount importance in ensuring the safe and stable operation of the power grid.
Junxin Chen +3 more
doaj +1 more source
Evaluation of Lightning Impulse Test by Frequency Response Analysis [PDF]
In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response.
RamÃrez, Jorge, Valecillos, Baudilio