Results 121 to 130 of about 855,147 (298)

Transient Stability Analysis of Power Systems via Occupation Measures [PDF]

open access: yesarXiv, 2018
We propose the application of occupation measure theory to the classical problem of transient stability analysis for power systems. This enables the computation of certified inner and outer approximations for the region of attraction of a nominal operating point.
arxiv  

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Automated rapidplan model validation using Eclipse scripting API

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract RapidPlan offers efficiency gains and quality improvements in treatment planning. Prior to its use in the clinic, it requires an extensive validation procedure in which established clinical plans and those generated by the model are compared. The manual iterative nature of this process is resource intensive, as numerous iterations are required
Bradley Beeksma   +2 more
wiley   +1 more source

Beam model development and clinical experience with RadCalc for treatment plan quality assurance in online adaptive workflow with an MR‐linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose The aim of this work was to report on the optimization, commissioning, and validation of a beam model using a commercial independent dose verification software RadCalc version 7.2 (Lifeline Software Inc, Tyler, TX, USA), along with 4 years of experience employing RadCalc for offline and online monitor unit (MU) verification on the ...
Urszula Jelen   +3 more
wiley   +1 more source

Comprehensive end‐to‐end dosimetry audit for stereotactic body radiotherapy in spine, lung, and soft tissue

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To create and conduct a comprehensive onsite end‐to‐end dosimetry audit to assess treatment accuracy of spine, lung, and soft tissue Stereotactic Body Radiotherapy (SBRT) across Australian and New Zealand (ANZ) radiotherapy centers. Methods The Australian Clinical Dosimetry Service (ACDS) anthropomorphic thorax phantom underwent a CT ...
Maddison Shaw   +8 more
wiley   +1 more source

Performance evaluation capabilities for the design of physical systems [PDF]

open access: yes
The results are presented of a study aimed at developing and formulating a capability for the limiting performance of large steady state systems. The accomplishments reported include: (1) development of a theory of limiting performance of large systems ...
Pilkey, W. D., Wang, B. P.
core   +1 more source

CNS Mitochondria‐Derived Vesicle in Blood: Potential Biomarkers for Brain Mitochondria Dysfunction

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Mitochondrial dysfunction is a hallmark of neurodegenerative diseases like Alzheimer's (AD) and Parkinson's (PD). Our goal was to develop practical, noninvasive methods to assess mitochondrial status through the detection of mitochondria‐derived vesicles (MDVs).
Qi Liu   +12 more
wiley   +1 more source

EEG Response to Sedation Interruption Complements Behavioral Assessment After Severe Brain Injury

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Accurate assessment of the level of consciousness and potential to recover in patients with severe brain injury underpins crucial decisions in the intensive care unit but remains a major challenge for the clinical team. The neurological wake‐up test is a widely used assessment tool. However, many patients' behavioral responses during
Charlotte Maschke   +12 more
wiley   +1 more source

Home - About - Disclaimer - Privacy