Results 121 to 130 of about 892 (179)
Design and Performance Validation of a High-Voltage Controller for MFC Piezoelectric Sensing and Actuation. [PDF]
Zhu Q, Qiu J, Lei H.
europepmc +1 more source
Development of a Multi-Channel Ultra-Wideband Electromagnetic Transient Measurement System. [PDF]
He S, Chen X, Zhang B, Song L.
europepmc +1 more source
Dynamic Lissajous patterns for real time identification and localization of power quality disturbance. [PDF]
Sinha P +8 more
europepmc +1 more source
Multi-timescale energy-aware grid-forming control with self-tuning virtual inductance for battery lifetime enhancement. [PDF]
Zheng L, Liu X.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Transient Overvoltages in Alternator Systems
SAE Technical Paper Series, 1973<div class="htmlview paragraph">Failure of electronic equipment in the alternator system will occur only under fault conditions. Overvoltage levels generated by the alternator and external equipment are discussed. Safe operation can be ensured by high voltage rating or by absorbing energy to reduce the transient voltage.
A. W. Winkley, M. J. Allport
openaire +1 more source
Transient overvoltages on power systems
IEE Proceedings C Generation, Transmission and Distribution, 1986Power systems are subjected to many forms of transient phenomena brought about essentially by sudden changes in the steady state values of voltages or currents. Such changes may be the result of a lightning stroke, some malfunction of the system or be brought about by the switching of a circuit either to clear a fault or as a normal operational ...
J.P. Bickford, A.G. Heaton
openaire +1 more source
Galvanostatic transients and crystallization overvoltage
Canadian Journal of Chemistry, 1978The theory of galvanostatic transients is extended to include the formation of a three-dimensional crystalline layer. The mechanism of formation of this layer is assumed to be one of nucleation and subsequent growth of randomly distributed nuclei on the electrode surface.
Stephen Fletcher, Arthur Smith
openaire +1 more source
Transient overvoltages and power-line terminations
Proceedings of the Institution of Electrical Engineers, 1966The paper outlines an investigation which was initiated to obtain an understanding of the mechanism by which overvoltages, of sufficient magnitude to cause flashover, are produced on a line section which forms part of a 132kV system. The line is terminated at one end with a series-connected inductor; the overvoltage occurs when the line is initially ...
A.G. Heaton, I.A. Reid
openaire +2 more sources
Very first transient overvoltages in GIS
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002A differentiating/integrating (D/I) system which does not change GIS (gas insulated substation) configuration is developed for the measurement of very fast transient overvoltages (VFTO) occurring in GIS. Then the numerical computation of VFTO is studied on the base of field measurement results.
null Zhang Wenyuan +2 more
openaire +1 more source

