Results 141 to 150 of about 892 (179)
Some of the next articles are maybe not open access.
Transient overvoltages and distance protections: problems and solutions
10th IET International Conference on Developments in Power System Protection (DPSP 2010). Managing the Change, 2010This paper investigates the relationship between post fault transient overvoltages and the functionality of the numerical distance protection. The study is conducted on a 66 kV network with a neutral earth resistor as method to earth the power system.
L. Torelli, S. Moorthy
openaire +1 more source
Overvoltage transient protection network design
Proceedings of the International Conference on Electromagnetic Interference and Compatibility, 1999Transient over-voltages caused by lightning, couples on to data communication or instrumentation signal lines and introduce serious fault alarm conditions and damage instrumentation electronics. Protection circuits to minimise the transient over-voltage are commercially available for variety of installation requirements.
openaire +1 more source
Transient overvoltages in a railway system during braking
2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America (T&D-LA), 2010This paper presents an overvoltage analysis in the dc catenary of The Metro de Medellin railway system. The main objective is to study the sources of damages of motors in the trains. It was achieved a detailed study beginning with the direct measurement of variables and then the construction of a digital model in PSCAD-EMTDC.
Mario A. Suarez +2 more
openaire +1 more source
Analysis of real overvoltage transient in a TLM-modeled
Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation, 2010This paper presents the behavior of a grounding mesh in presence of a high-frequency overvoltage transient caused by switch closing in electrical substations and atmospheric discharges. The simulation of the mesh is based on Transmission Line Method (TLM).
L. H. A. de Medeiros +4 more
openaire +1 more source
Calculation of Very Fast Transient Overvoltages in GIS
2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific, 2005This paper refers to 500 kV gas insulated substation (GIS) of the Tian Huangping pumped storage power station in East China power system. With the current electro-magnetic transient program (EMTP) in world, we simulate and calculate the very fast transient overvoltages (VFTO) caused by operating of disconnect switch (DS), and the factors that ...
Tiechen Lu, Bo Zhang
openaire +1 more source
A new method of transient overvoltage monitoring for substation
Proceedings. International Conference on Power System Technology, 2003The electromagnetic voltage transformer or capacitive divider is usually used to monitor overvoltage in power system. The transient response of electromagnetic voltage transformer is slow, so they can't reflect transient overvoltage accurately. Optical voltage sensor is a new type of voltage measuring appliance, which measures voltage by crystal ...
null Xiufang Jia +3 more
openaire +1 more source
Transient overvoltage study of an Island wind farm
2012 47th International Universities Power Engineering Conference (UPEC), 2012It has slowly becoming the norm for countries to include renewable energy as a percentage of their electricity generation mix. Wind is arguably the most mature technology of the available sources of renewable energy. Globally, the inclusion of wind farms in the generation of electricity is significant, both economically and environmentally.
Newman Malcolm, Raj K. Aggarwal
openaire +1 more source
Study of lightning overvoltage transients using ATP
2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015], 2015Rapid development of transmission and distribution network requires an in-depth research and development work for their proper operation. Protection of the components used in transmission and distribution substations is one of the most important factors which must be taken care of in a very efficient manner. In this paper the analysis of lightning over
T. Chatterjee, A. Mukherjee
openaire +1 more source
Very Fast Transient Overvoltage of UHVAC System
2017Compared with 500 kV EHV GIS substation, 1000 kV UHV GIS/HGIS substation has different characteristics in terms of switchgear, system structure, insulation margin, requirements on safety and stability and importance. And the hazardness of very fast transient overvoltage (VFTO) on UHV GIS is much heavier than that in 500 kV power system.
Yang Li, Guoming Ma, Hao Zhou
openaire +1 more source
Suppression of Transient Overvoltages on Instrumentation Wiring Systems
IEEE Transactions on Industry Applications, 1985Modern electronic analog instrumentation equipment is vulnerable to damage by transient overvoltages appearing on signal and power supply wiring. Experience with overvoltages and relatively simple techniques to avoid damage are discussed.
openaire +1 more source

