Results 161 to 170 of about 1,696 (209)
Some of the next articles are maybe not open access.
Transient overvoltages on power systems
IEE Proceedings C Generation, Transmission and Distribution, 1986Power systems are subjected to many forms of transient phenomena brought about essentially by sudden changes in the steady state values of voltages or currents. Such changes may be the result of a lightning stroke, some malfunction of the system or be brought about by the switching of a circuit either to clear a fault or as a normal operational ...
J.P. Bickford, A.G. Heaton
openaire +1 more source
Galvanostatic transients and crystallization overvoltage
Canadian Journal of Chemistry, 1978The theory of galvanostatic transients is extended to include the formation of a three-dimensional crystalline layer. The mechanism of formation of this layer is assumed to be one of nucleation and subsequent growth of randomly distributed nuclei on the electrode surface.
Stephen Fletcher, Arthur Smith
openaire +1 more source
Transient overvoltages and power-line terminations
Proceedings of the Institution of Electrical Engineers, 1966The paper outlines an investigation which was initiated to obtain an understanding of the mechanism by which overvoltages, of sufficient magnitude to cause flashover, are produced on a line section which forms part of a 132kV system. The line is terminated at one end with a series-connected inductor; the overvoltage occurs when the line is initially ...
A.G. Heaton, I.A. Reid
openaire +2 more sources
Calculation of energy in transient overvoltages
National Symposium on Electromagnetic Compatibility, 2003It is argued that the calculation of the energy in a transient overvoltage using the time integral of V/sup 2/(t)/Z, where Z has the default value of 50 Omega and the voltage, V(t), is that between the hot conductor in the AC line and ground, is inaccurate. A quantitative error analysis is presented that uses an artificial AC line network to simulate a
openaire +1 more source
Very first transient overvoltages in GIS
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002A differentiating/integrating (D/I) system which does not change GIS (gas insulated substation) configuration is developed for the measurement of very fast transient overvoltages (VFTO) occurring in GIS. Then the numerical computation of VFTO is studied on the base of field measurement results.
null Zhang Wenyuan +2 more
openaire +1 more source
Research on Transient model of Transient Enclosure Overvoltage in UHV GIS
2019 Chinese Automation Congress (CAC), 2019With the increase of voltage grade, the effects of electromagnetic transient process of power system should not be ignored. In order to provide the theoretical reference for UHV substation, continuous optimization models is very important. In this thesis, we do some calculations and analysis of the TEV which occurs in 1100kV substation of south ...
Qiang Zhang +6 more
openaire +1 more source
Computation of Very Fast Transient Overvoltages in Transformer Windings
IEEE Power Engineering Review, 2002The paper deals with the computation of very fast transient overvoltages (VFTO) in transformer windings. For this purpose an algorithm is developed. The applied algorithm uses a hybrid model, which is a combination of the multi-conductor transmission line model (MTLM) and the single-transmission line model (STLM).
Popov, M. (author) +3 more
openaire +2 more sources
Transient overvoltages in mine power systems
2022This thesis investigates the nature and magnitude of switching transient overvoltages that can be expected in inductively grounded underground coal mines. Computer models of power system equipment have been developed to analyse single-phase fault isolations; motor starts (including prestriking) and motor turn offs.
openaire +1 more source
Measuring transient overvoltage on instrument feeders
Radio and Electronic Engineer, 1964The problem of obtaining information on unwanted transient voltages which may damage semiconductors is considered in relation to electricity generating and switching stations. It is concluded that the collection of data from actual sites by an unattended monitoring instrument would yield valuable information with the minimum effort.
openaire +1 more source
Transient overvoltage protection for UPS applications
2011 IEEE Trondheim PowerTech, 2011Uninterruptible Power Supplies (UPS) are used to ensure a continuous and reliable supply to critical loads. Different UPS technologies are available, offering different levels of load protection and power conditioning. This paper discusses various UPS topologies and operating modes, identifying the paths over which a surge or transient voltage may ...
openaire +1 more source