Results 41 to 50 of about 144,974 (202)

Bound states in the continuum driven by AC fields [PDF]

open access: yes, 2013
We report the formation of bound states in the continuum driven by AC fields. This system consists of a quantum ring connected to two leads. An AC side-gate voltage controls the interference pattern of the electrons passing through the system.
DomĂ­nguez-Adame, F.   +2 more
core   +2 more sources

Multiterminal Hybrid DC Line Protection Based on Intrinsic Mode Energy Entropy

open access: yesFrontiers in Energy Research, 2022
In view of the UHV multiterminal hybrid DC transmission system, the DC line protection with universal applicability, fast response speed, stability, and reliability is particularly important for its safe and economic operation.
Chao Xing   +8 more
doaj   +1 more source

Design of an integrated shallow water wave experiment [PDF]

open access: yes, 1997
The experimental design and instrumentation for an integrated shallow-water surface gravity wave experiment is discussed. The experiment required the measurement of the water surface elevation, meteorological parameters, and directional spectra at a ...
Dalton, M. A.   +3 more
core   +1 more source

Study on the overturning stability of transmission poles in the Yellow River silt under the influence of wind and rain

open access: yesResults in Engineering
To evaluate the overturning stability of transmission line poles under combined wind and rainfall conditions in the Yellow River beach area, indoor simulation tests and numerical simulations were conducted.
Changbin Yan   +6 more
doaj   +1 more source

Super High-Selectivity Fifth-Order Bandpass Filter with Twelve Transmission Zeros [PDF]

open access: yesRadioengineering, 2018
A fifth-order bandpass filter (BPF) with super high selectivity using three pairs of coupled lines and two open stubs is proposed. Twelve transmission zeros (TZs) from 0 to 2f_0 (f_0 denotes center frequency of the passband) and five transmission poles ...
Y.-J. Cai   +3 more
doaj  

Nondestructive Inspection of Reinforced Concrete Utility Poles with ISOMAP and Random Forest

open access: yesSensors, 2018
Reinforced concrete poles are very popular in transmission lines due to their economic efficiency. However, these poles have structural safety issues in their service terms that are caused by cracks, corrosion, deterioration, and short-circuiting of ...
Saeed Ullah, Minjoong Jeong, Woosang Lee
doaj   +1 more source

Natural durability of Eucalyptus species harvested as electricity transmission poles in two different ecological zones of Ghana

open access: yesScientific African
This study assessed the possibility and feasibility of using two Eucalyptus species for electricity transmission poles in Ghana as a means of minimizing the import of transmission poles in the country.
Francis Wilson Owusu   +6 more
doaj   +1 more source

Residual life assessment of overhead transmission lines 110 kV and above and determination of their reconstruction terms

open access: yesE3S Web of Conferences, 2017
In this article is given a method for assessment the residual life of overhead transmission lines on reinforced concrete supports with centrifuged poles. Reinforced concrete poles of supports, wires and lightning protection cables are adopted as the main
Uteuliyev Bauyrzhan
doaj   +1 more source

Design of Multiplexers for IoT-Based Applications Using Stub-Loaded Coupled-Line Resonators

open access: yesMicromachines, 2023
This paper presents the design of microstrip-based multiplexers using stub-loaded coupled-line resonators. The proposed multiplexers consist of a diplexer and a triplexer, meticulously engineered to operate at specific frequency bands relevant to IoT ...
Muhammad Idrees   +5 more
doaj   +1 more source

Scattering and bound states of spin-0 particles in a nonminimal vector double-step potential

open access: yes, 2012
The problem of spin-0 particles subject to a nonminimal vector double-step potential is explored in the context of the Duffin-Kemmer-Petiau theory. Surprisingly, one can never have an incident wave totally reflected and the transmission amplitude has ...
A.S. de Castro   +2 more
core   +1 more source

Home - About - Disclaimer - Privacy