Impact of Duration of Catheterization on the Success Rate of Trial Without Catheter in Acute Urinary Retention Due to Benign Prostatic Enlargement. [PDF]
Ghazanfar NA +5 more
europepmc +1 more source
Continuum Mechanics Modeling of Flexible Spring Joints in Surgical Robots
A new mechanical model of a tendon‐actuated helical extension spring joint in surgical robots is built using Cosserat rod theory. The model can implicitly handle the unknown contacts between adjacent coils and numerically predict spring shapes from straight to significantly bent under actuation forces.
Botian Sun +3 more
wiley +1 more source
Background Catheter ablation is superior to drug therapy in selected atrial fibrillation (AF) patients, yet the impact of prior non-ablation rhythm control remains unclear. Methods We analyzed data from Catheter Ablation vs.
Wenli Dai +10 more
doaj +1 more source
Objective: Indwelling transurethral catheter is frequently used after gynecological surgeries in order to prevent urinary retention. There is controversy about the ideal time to remove the catheter after surgery.
Bharti Joshi +3 more
doaj +1 more source
The predictive value of intravesical prostatic protrusion on the outcome of trial without catheter in patients with acute urinary retention from benign prostatic hyperplasia at Jos University Teaching Hospital, Nigeria: a prospective observational study. [PDF]
Oshagbemi AO +5 more
europepmc +1 more source
Tumbling Magnetic Microrobots for Targeted In Vivo Drug Delivery in the GI Tract
We introduce a microrobot design and integrated system for on‐demand targeted drug release in the gastrointestinal tract. The microrobot has an embedded magnet for actuation with external magnetic fields and is visualized in real time using ultrasound. It has two drug release ports sealed with a thermally sensitive wax. Local heating of the wax using a
Aaron C. Davis +7 more
wiley +1 more source
Waveguide Photoactuators: Materials, Fabrication, and Applications
Waveguide photoactuators convert guided light into mechanical motion. Their tethered‐flexible design enables minimally invasive surgery and confined‐space robotics. This review aims to guide materials selection, device design, and system integration, accelerating the transition of waveguide photoactuators from laboratory prototypes to versatile ...
Minjie Xi +4 more
wiley +1 more source
Miniaturized Magnetic Tip Design for Endoluminal Vine Robot Navigation
A magnetic tip mount is designed for a miniaturized 7 mm soft‐growing vine robot to enable wireless magnetic steering and onboard imaging, while preserving a 3 mm working channel. The internal–external ring magnets design balances magnetic attachment with low eversion pressure. Experiments demonstrate ±90° steering, 34 mm bending radius, and successful
Andrea Yanez Trujillo +4 more
wiley +1 more source
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin +3 more
wiley +1 more source
Strategic Design of Soft Actuators in Translational Medical Robotics for Human‐Centered Healthcare
Soft robotics enables biocompatible, compliant medical devices, but clinical translation requires design‐driven engineering beyond materials. This perspective reviews implantable, surgical, and wearable systems by actuation mechanism, highlighting how optimized architectures and integration improve mechanical interfacing, adaptability, and durability ...
Ho Jun Jin +3 more
wiley +1 more source

