Results 61 to 70 of about 2,868 (157)

Inflammatory Pseudotumor After Total Hip Arthroplasty‐An Increasingly Recognized Complication

open access: yesOrthopaedic Surgery, Volume 18, Issue 7, Page 1311-1327, July 2026.
This review systematically elucidates the clinical characteristics and management of inflammatory pseudotumor (IP) across different bearing surfaces, addressing a topic of increasing concern and providing a novel perspective. It synthesizes the five primary risk factors associated with IP, offering clinicians critical reference points.
Steve T. L. Pambayi   +8 more
wiley   +1 more source

Corrosion Damage in Retrieved CoCrMo/Ti‐6Al‐4V Modular Junctions in Femoral Revision Total Knee Components

open access: yesJournal of Biomedical Materials Research Part B: Applied Biomaterials, Volume 114, Issue 6, June 2026.
ABSTRACT Modularity in revision total knee arthroplasty (TKA) is prevalent; however, corrosion mechanisms at modular junctions in these devices are not well investigated compared to total hip arthroplasty (THA). This retrieval study analyzed corrosion damage on modular junctions of cobalt chromium molybdenum (CoCrMo) alloy femoral components with a ...
Hwaran Lee   +5 more
wiley   +1 more source

Advancements in Modelling the Tribocorrosion Current

open access: yesChemElectroChem
AbstractTribocorrosion in passive metals involves a complex and interactive mechanism between mechanical and electrochemical actions at a rubbing contact in a corrosive environment. The mechanical wear mechanism disrupts the passive film on the metal surface; and instantly, the metal repassivates and dissolves in the corrosive environment. This surface
Fayzi, Mohsen   +2 more
openaire   +4 more sources

Ti6Al4V‐Bioglass‐Copper Composites for Load‐Bearing Implants

open access: yesAdvanced Healthcare Materials, Volume 15, Issue 13, 3 April 2026.
We have designed and manufactured a novel Ti64‐based composite by adding 45S5 bioglass (BG) and copper (Cu). Adding BG on titanium improves wear resistance and biocompatibility, whereas Cu addition improves mechanical strength while providing inherent lifelong bacterial resistance.
Lochan Upadhayay   +3 more
wiley   +1 more source

Enhanced Surface Properties and In Vitro Corrosion Tests of Ti─Nb─Sn Coating on CoCrMo Alloy for Biomedical Applications

open access: yesPlasma Processes and Polymers, Volume 23, Issue 4, April 2026.
Ti–Nb–Sn thin films were deposited on CoCrMo alloy by DC magnetron sputtering to enhance surface performance for biomedical applications. The coating significantly improved corrosion resistance in PBS by reducing corrosion current density and increasing polarization resistance. Tribological tests under dry and PBS conditions revealed a marked reduction
Mevra Aslan Çakır
wiley   +1 more source

Role of nanomaterials on tribocorrosion

open access: yes, 2011
Tribocorrosion is the degradation of materials caused by simultaneous mechanical and chemical/electrochemical interactions between surfaces in relative motion, resulting in irreversible transformation of materials or of their functions.
Sankara Narayanan, T S N
core   +1 more source

Standardizing terms for tribocorrosion-associated adverse local tissue reaction in total hip arthroplasty

open access: yesArthroplasty Today, 2020
Recognizing and adopting standardized terms for adverse local tissue reaction associated with tribocorrosion in total hip arthroplasty are essential for clear scientific discourse and clinical communication.
Brian J. McGrory, MD, MS   +3 more
doaj   +1 more source

Titanium migration and bone response in loaded osseointegrated implants: ESEM‐EDX analysis in Macaca fascicularis

open access: yesJournal of Periodontology, Volume 97, Issue 3, Page 527-539, March 2026.
Abstract Background Titanium nanoparticle (TP) migration into peri‐implant bone may influence osseointegration. It remains unclear how loading protocols may affect TP distribution. This study aimed to detect TP in the bone around implants undergoing different loading protocols in Macaca fascicularis.
Fausto Zamparini   +8 more
wiley   +1 more source

Tribocorrosion – Insight into Material Degradation in Specific Environments

open access: yesThe Annals of “Dunarea de Jos” University of Galati. Fascicle IX, Metallurgy and Materials Science, 2014
Tribocorrosion is an irreversible surface degradation mechanism of a metallic and/or non-metallic material as a result of its physicochemical and mechanical interactions during relative motion (friction, sliding, impact, abrasion, erosion) in corrosive ...
Sorin-Bogdan BAŞA, Lidia BENEA
doaj  

Comparison of Intergranular Corrosion Resistance and Hardness between Nitrogen and Carbon Martensites in Stainless Steels

open access: yessteel research international, Volume 97, Issue 3, Page 1538-1546, March 2026.
By applying solution heat treatment after plasma nitriding, followed by requenching and tempering, researchers successfully obtained nitrogen‐rich martensite on AISI 409. This study compares the intergranular corrosion resistance and hardness of nitrogen‐rich martensite in AISI 409 with carbon‐rich martensite in AISI 420.
Pedro Victorio Caetano Abrantes Quadros   +2 more
wiley   +1 more source