Results 1 to 10 of about 795 (114)
Optimization of Two-Phase Ejector Mixing Chamber Length under Varied Liquid Volume Fraction [PDF]
The ejector performance varies with the mixing chamber length which is largely dependent on the fluid liquid volume fraction at the inlet. In this study, numerical simulations are conducted to optimize two mixing chamber lengths of a two-phase ejector ...
Jia Yan +3 more
doaj +2 more sources
In this paper, an experimental investigation of the performance improvement of a heat pump equipped with a two-phase ejector, called an “ejector–expansion heat pump (EEHP)”, is proposed. The system performance of the EEHP is compared with that of a vapor-
Wichean Singmai +2 more
doaj +3 more sources
In this paper, the performance enhancement of the two-phase ejector installed into the refrigeration system called an ejector-expansion refrigeration system (EERS) is investigated experimentally.
Kittiwoot Sutthivirode +1 more
doaj +1 more source
A Simple Design Approach of Two-Phase Ejectors for CO2 Transcritical Heat Pumps [PDF]
Integrating a two-phase ejector in mechanical vapor compression heat pumps is a practical and low-cost solution for improving performance and reducing energy consumption.
K. Ameur, Z. Aidoun
doaj +1 more source
Preliminary Design of the Two-Phase Ejector under Constant Area Mixing Assumption for 5 kW Experimental System [PDF]
Ejector expansion refrigeration cycle is the modification of the vapour compression refrigeration cycle with the implementation of a two-phase ejector and a vapour-liquid separator to improve the cycle performance.
Atmaca Ayşe Uğurcan +2 more
doaj +1 more source
A two-phase liquid-gas ejector with a supersonic nozzle is described in the article. The results of numerical modeling of the processes occurring in it and forming a two-phase jet are presented. The structure of a two-phase flow formed by the ejector and
I. A. Lepeshinsky +2 more
doaj +1 more source
When injectors are used in petroleum industries or sea water desalination system, it is a special case that the induced gas is accompanied by water, the ejector is in two-phase operation. In the present study, the ejector performance at two phase flow is
WeiXiong Chen +5 more
doaj +1 more source
An Object-Oriented R744 Two-Phase Ejector Reduced-Order Model for Dynamic Simulations
The object-oriented two-phase ejector hybrid reduced-order model (ROM) was developed for dynamic simulation of the R744 refrigeration system. OpenModelica software was used to evaluate the system’s performance. Moreover, the hybrid ROM results were
Michal Haida +6 more
doaj +1 more source
Recently, with the appearance of the two-phase flow ejector in refrigeration air conditioning and heat pump systems, the efficiency of the cycle has largely been improved in comparison with that of conventional cooling and heating systems.
Yosuke KAWAMURA, Masafumi NAKAGAWA
doaj +1 more source
A two-phase flow ejector is an important part of a water mist fire suppression system, and these devices have become a popular research topic in recent years. This paper proposes a supersonic ejector that aims to improve the efficiency of water mist fire
Shizhen Li +4 more
doaj +1 more source

