Results 11 to 20 of about 133,175 (159)

Comparison of sysmex UF-5000 flow cytometer and fuchs-rosenthal chamber urine sediment analysis [PDF]

open access: yesMedicine Science, 2022
Urine analysis is a routine test performed in clinical practice. Urine sediment analysis is a part of urinalysis that provides precious information to laboratory professionals.
Ozlem Unay Demirel   +1 more
doaj   +3 more sources

Performance verification of the new UF-1500 urine particle analyser: a new opportunity for small and medium laboratories [PDF]

open access: yesPractical Laboratory Medicine
Background: The UF-1500 is the new fully automated urine particle analyser by Sysmex specifically tailored for small and medium laboratories. This study aim to validate its analytical and diagnostic performance.
Giulia Previtali   +14 more
doaj   +4 more sources

A performance comparison of the fully automated urine particle analyzer UF-5000 with UF-1000i and Gram staining in predicting bacterial growth patterns in women with uncomplicated urinary tract infections [PDF]

open access: yesBMC Urology, 2021
Background The aim of this study was to compare the performance of the new flow cytometer UF-5000 with the UF-1000i and Gram staining for determining bacterial patterns in urine samples.
Stephen Shei-Dei Yang   +3 more
doaj   +2 more sources

[Evaluation of Sysmex UF-5000 flow cytometer flag BACT-info for Gram discrimination in urinary tract infection]. [PDF]

open access: yesRev Esp Quimioter, 2023
Introduction. Urine culture as a gold standard for the diagnosis of urinary tract infection (UTI) involves a considerable workload in Clinical Microbiology Departments, due to the high number of samples received that will ultimately be negative. Therefore, it is necessary to use screening systems that also reduce the turnaround time for UTI diagnosis ...
Angulo-López I   +4 more
europepmc   +3 more sources

Performance of Sysmex UF-5000 for candiduria screening [PDF]

open access: yesThe new microbiologica, 2022
In this study, we tested the performance of the Sysmex UF-5000 system to detect yeast-like cell (YLC) counting to screen for candiduria. Urine samples were screened for leukocyte and yeast amount by flow cytometry and results were compared with fungal culture results. A total of 56,749 urine samples were enrolled in this study.
Özgür, Yanılmaz, Arzu, Akşit İlki
core   +5 more sources

Diagnostic Characteristics of Urinary Red Blood Cell Distribution Incorporated in UF-5000 for Differentiation of Glomerular and Non-Glomerular Hematuria. [PDF]

open access: yesAnn Lab Med, 2022
Automated urine sediment analysis has been developed to address the limitations of microscopic examination of dysmorphic red blood cells (RBCs). We evaluated the urinary RBC distribution (URD) parameter of a recently launched automated urinary flow cytometry analyzer, UF-5000 (Sysmex, Kobe, Japan), to differentiate glomerular hematuria (GH) from non-GH
Cho H   +5 more
europepmc   +4 more sources

Diagnostic Accuracy of Urine Flow Cytometry (UF) in Urinary Tract Infection (UTI) Detection and Management: A Systematic Review and Meta-Analysis [PDF]

open access: yesDiagnostics
Background: Urinary tract infections (UTIs) are prevalent bacterial infections associated with significant morbidity and healthcare burden. Traditional diagnosis relies on urine culture, which is limited by long turnaround times and potential ...
Kai-Wei Chang   +4 more
doaj   +2 more sources

Selection of Unnecessary Urine Culture Specimens Using Sysmex UF-5000 Urine Flow Cytometer

open access: yesAnnals of Clinical Microbiology, 2018
Background: Urine culture is one of the most frequently requested tests in microbiology. Automated urine analyzers yield much infection-related information.
Duyeal Song   +4 more
doaj   +2 more sources

Assessment of the Diagnostic Value of the UF-5000 Parameter Atyp.C in Upper Tract Urothelial Carcinoma. [PDF]

open access: yesCancer Diagn Progn
Background/Aim: Urine cytology is widely used for diagnosing urothelial carcinoma. However, it has limited sensitivity, particularly in upper tract urothelial carcinoma. The UF-5000 automated urine analyzer includes the research parameter Atyp.C, which quantifies cells with a high nuclear-to-cytoplasmic ratio.
Shigehisa R   +19 more
europepmc   +2 more sources

Enhancing clinical decision-making: Sysmex UF-5000 as a screening tool for bacterial urinary tract infection in children. [PDF]

open access: yesPLoS One
Background A rapid screening test for urinary tract infections (UTIs) in children is needed to avoid unnecessary cultures and provide prompt reports to make appropriate clinical decisions. We have evaluated for the first time the performance of the Sysmex UF-5000 flow cytometer as a screening tool for UTIs in children.
Liu P   +6 more
europepmc   +3 more sources

Home - About - Disclaimer - Privacy