Results 61 to 70 of about 3,039 (204)

3D inversion recovery ultrashort echo time MRI can detect demyelination in cuprizone-treated mice

open access: yesFrontiers in Neuroimaging
PurposeTo test the ability of inversion-recovery ultrashort echo time (IR-UTE) MRI to directly detect demyelination in mice using a standard cuprizone mouse model.MethodsNon-aqueous myelin protons have ultrashort T2s and are “invisible” with conventional
Adam C. Searleman   +11 more
doaj   +1 more source

A pilot study of short T2* measurements with ultrashort echo time imaging at 0.35 T

open access: yesBioMedical Engineering OnLine, 2018
Purpose Ultrashort echo time (UTE) sequences play a key role in imaging and quantifying short T2 species. However, almost all of the relevant studies was conducted at relatively high fields. The purpose of this work was to further explore the feasibility
Xiuyuan Chen, Bensheng Qiu
doaj   +1 more source

Advanced magnetic resonance imaging of cartilage components in haemophilic joints reveals that cartilage hemosiderin correlates with joint deterioration. [PDF]

open access: yes, 2019
IntroductionEvidence suggests that toxic iron is involved in haemophilic joint destruction.AimTo determine whether joint iron deposition is linked to clinical and imaging outcomes in order to optimize management of haemophilic joint disease.MethodsAdults
Barnes, Richard FW   +7 more
core   +2 more sources

Ultrashort echo time (UTE) MRI of the lung: Assessment of tissue density in the lung parenchyma [PDF]

open access: yesMagnetic Resonance in Medicine, 2010
AbstractNonuniform disruption of lung architecture is usually assessed by CT, which carries potential radiation risk. Here we report our use of a three‐dimensional ultrashort echo time MR method to image the lungs of normal mice at different positive end‐expiratory pressures in a 3‐T clinical MR system.
Osamu, Togao   +4 more
openaire   +2 more sources

Comparison of Signal‐ and Volume‐Based Ventilation‐Weighted Assessment Using 3D FLORET UTE MRI in Patients With Various Pulmonary Disease

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose 3D free‐breathing, proton, contrast‐agent‐free MR methods are increasingly used for pulmonary ventilation‐weighted measurements. The methods are split between: (1) signal‐based, which rely on lung parenchyma signal changes during respiration, and (2) volume‐based that utilize the Jacobian determinant of deformation fields from the ...
Filip Klimeš   +12 more
wiley   +1 more source

Quantitative ultrashort echo time (UTE) MRI of human cortical bone: Correlation with porosity and biomechanical properties [PDF]

open access: yesJournal of Bone and Mineral Research, 2011
Abstract In this study we describe the use of ultrashort echo time (UTE) magnetic resonance imaging (MRI) to evaluate short and long T2* components as well as the water content of cortical bone. Fourteen human cadaveric distal femur and proximal tibia were sectioned to produce 44 rectangular slabs of cortical bone for quantitative UTE MR
Won C, Bae   +5 more
openaire   +2 more sources

The dataset on the clipped cerebral aneurysm and their radiological findings in three-dimensional computed tomography, time-of-flight magnetic resonance angiography (TOF-MRA), and Pointwise Encoding Time Reduction with Radial Acquisition (PETRA)-MRA

open access: yesData in Brief, 2021
These data present the 141 intracranial arterial branches' visibilities near the 72 cerebral aneurysms in postoperative 58 patients treated with titanium or cobalt-chromium-nickel-molybdenum (CCNM) alloy clips.
Akihiro Nishikawa   +5 more
doaj   +1 more source

High‐resolution ultrashort echo time (UTE) imaging on human knee with AWSOS sequence at 3.0 T [PDF]

open access: yesJournal of Magnetic Resonance Imaging, 2011
AbstractPurpose:To demonstrate the technical feasibility of high‐resolution (0.28–0.14 mm) ultrashort echo time (UTE) imaging on human knee at 3T with the acquisition‐weighted stack of spirals (AWSOS) sequence.Materials and Methods:Nine human subjects were scanned on a 3T MRI scanner with an 8‐channel knee coil using the AWSOS sequence and isocenter ...
Yongxian, Qian   +3 more
openaire   +2 more sources

Coil Sketching for Fast and Efficient 4D Lung MRI Reconstruction

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 4, Page 2241-2253, April 2026.
ABSTRACT Purpose To develop and evaluate a memory‐efficient and accelerated reconstruction framework for respiratory‐resolved 4D lung MRI using coil sketching and Toeplitz approximation, enabling high‐quality motion‐compensated low‐rank (MoCo‐LR) reconstructions on clinically accessible GPU hardware.
Joseph W. Plummer   +7 more
wiley   +1 more source

Ultrashort Echo Time and Fast Field Echo Imaging for Spine Bone Imaging with Application in Spondylolysis Evaluation

open access: yesComputation
Isthmic spondylolysis is characterized by a stress injury to the pars interarticularis bones of the lumbar spines and is often missed by conventional magnetic resonance imaging (MRI), necessitating a computed tomography (CT) for accurate diagnosis.
Diana Vucevic   +7 more
doaj   +1 more source

Home - About - Disclaimer - Privacy