Results 21 to 30 of about 71,330 (257)
Overview of Ultrasound Detection Technologies for Photoacoustic Imaging
Ultrasound detection is one of the major components of photoacoustic imaging systems. Advancement in ultrasound transducer technology has a significant impact on the translation of photoacoustic imaging to the clinic.
Rayyan Manwar +2 more
doaj +1 more source
We present a back-to-back (BTB) structured, dual-mode ultrasonic device that incorporates a single-element 5.3 MHz transducer for high-intensity focused ultrasound (HIFU) treatment and a single-element 20.0 MHz transducer for high-resolution ultrasound ...
Hae Gyun Lim +9 more
doaj +1 more source
The Influence of Air Pressure on the Dynamics of Flexural Ultrasonic Transducers
The flexural ultrasonic transducer comprises a piezoelectric ceramic disc bonded to a membrane. The vibrations of the piezoelectric ceramic disc induce flexural modes in the membrane, producing ultrasound waves. The transducer is principally utilized for
Andrew Feeney +3 more
doaj +1 more source
Design and Fabrication of Double-Focused Ultrasound Transducers to Achieve Tight Focusing
Beauty treatment for skin requires a high-intensity focused ultrasound (HIFU) transducer to generate coagulative necrosis in a small focal volume (e.g., 1 mm3) placed at a shallow depth (3–4.5 mm from the skin surface).
Jihun Jang, Jin Ho Chang
doaj +1 more source
Introduction: Ultrasound hypotension protocols (UHP) involve imaging multiple body areas, each with different transducers and imaging presets. The time for task switching between presets and transducers to perform an UHP has not been previously studied ...
Linda Sabbadini +4 more
doaj +1 more source
The current ‘active’ solution to overcome the impediment of ultrasound wave degradation associated with transit-time variation in complex tissue structures, such as the skull, is to vary the transmission delay of ultrasound pulses from individual ...
Christian M Langton +2 more
doaj +1 more source
Circulating microRNAs as biomarkers of cachexia and sex‐specific cancer in senior dogs. In 25 client‐owned dogs, four circulating miRNAs (miR‐15a, miR‐15b, miR‐16, miR‐140) were downregulated in cachexia, with miR‐16 the strongest individual biomarker (AUC = 0.899).
Soon‐Seok Park +6 more
wiley +1 more source
Integration of porous graphene and 3D-printed piezopolymer for flexible ultrasound transducers
Ultrasound technology is crucial in diagnostic imaging, making it widely used in medical applications. However, traditional ultrasound transducers face limitations in flexibility and ease of fabrication, leading to the exploration of thin-film and ...
Shirin Movaghgharnezhad +6 more
doaj +1 more source
Ultrasound is employed in, e.g., non-destructive testing and environmental sensing. Unfortunately, conventional single-element ultrasound probes have a limited acoustic aperture.
Tom Sillanpää +6 more
doaj +1 more source
This study identifies somatostatin receptor 4 (Sstr4) as a critical tumor suppressor against skin and head/neck cancers (HNSCC, cSCC, and BCC). The loss of Sstr4 removes a check on cell growth, causing hyperactivation of the MAPK‐ERK signaling pathway (↑).
Ali Taqvi +6 more
wiley +1 more source

