Results 1 to 10 of about 50,303 (205)

Point Estimate Method for Voltage Unbalance Evaluation in Residential Distribution Networks with High Penetration of Small Wind Turbines [PDF]

open access: yesEnergies, 2014
Voltage unbalance (VU) in residential distribution networks (RDNs) is mainly caused by load unbalance in three phases, resulting from network configuration and load-variations.
Chao Long   +3 more
doaj   +4 more sources

Improved Method for Determining Voltage Unbalance Factor Using Induction Motors

open access: yesEnergies, 2022
This work shows an alternative method to determine the Voltage Unbalance Factor in a power grid by using both the mean value of the line voltages and Current Unbalance Factor in induction motors. Twenty unbalanced voltage points on three induction motors
Luis Guasch-Pesquer   +3 more
doaj   +2 more sources

Detection of incipient rotor unbalance fault based on the RIME-VMD and modified-WKN [PDF]

open access: yesScientific Reports
Due to the high incidence and inconspicuous initial characteristics of rotor unbalance faults, the detection of incipient unbalance faults is becoming a very challenging problem.
Qian Wang, Shuo Hu, Xinya Wang
doaj   +2 more sources

Flow stability and distribution in horizontal serpentine tube bundles with vertical headers [PDF]

open access: yesHeliyon
Particle-based systems have immense potential for combining thermal energy storage (TES) with renewable energy sources. The so-called sandTES system, which is an active TES system, utilizes sand or other small particles as a storage material and consists
Viktoria Illyés   +4 more
doaj   +2 more sources

AI-based hybrid power quality control system for electrical railway using single phase PV-UPQC with Lyapunov optimization [PDF]

open access: yesScientific Reports
This research paper presents an advanced AI-driven hybrid power quality management system for electrical railways that addresses critical challenges in 25 kV AC traction networks through a novel integration of single-phase PV-UPQC with ANN-Lyapunov ...
D. K. Nishad   +4 more
doaj   +2 more sources

Comprehensive Modeling of Induction Motor Imbalance Condition to ‎Precise Assessment of Steady State Performance Based on Complex ‎Current Unbalance Factor [PDF]

open access: yesمجله مدل سازی در مهندسی, 2021
After a comprehensive study of voltage unbalance issue, this ‎paper presents the defects of some unbalance factors and ‎concentrates on the importance of considering the angle of ‎complex voltage unbalance factor (CVUF) in order to ‎unbalanced condition ...
Saeed Maghsoodi   +3 more
doaj   +1 more source

INVESTIGATION OF LOAD CURVE UNBALANCE FACTOR IN 0.4 KV ELECTRIC NETWORKS IN ARMENIA

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2005
The purpose of the paper is to investigate a load curve unbalance factor which is an integrated indicator of electric energy consumption character in 0.4 kV electric networks.
T. S. Gnuni
doaj   +1 more source

A Decoupling Algorithm-Based Technology for Predicting and Regulating the Unbalance of Aircraft Rotor Assembly Considering Manufacturing Errors

open access: yesMachines, 2023
Rotor unbalance is the most important factor affecting the dynamic performance of aircraft engines. The existing unbalance prediction and control methods are insufficient for multi-stage rotors.
Yingjie Zhao   +5 more
doaj   +1 more source

Performance Analysis of the Slip Power Recovery Induction Motor Drive System Under Unbalance Supply Voltages

open access: yesAdvances in Electrical and Electronic Engineering, 2021
This paper develops a mathematical model for analyzing the steady-state performance of the Slip Power Recovery Induction Motor Drive System (SPRIMDS) which operates under unbalance supply voltage conditions.
Hilmi Fadhil Ameen, Fadhil Toufick Aula
doaj   +1 more source

Dependancy of Three Phase Induction Motor Derating Aspects on Complex Voltage Unbalance Factor: A Calorimetric and Finite Element Simulation Study

open access: yesIEEE Access, 2021
It is well known that three-phase induction motors have to be derated in the presence of supply voltage unbalance (negative sequence) exceeding a stipulated limit of 1% based on several widely used standards.
Pathum Sudasinghe   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy