Results 261 to 270 of about 93,852 (297)
Some of the next articles are maybe not open access.
Voltage Source Converter Control Under Unbalanced Grid Voltage
2021The conventional control of the voltage source converter (VSC) assumes that the input voltage is balanced. However, unbalanced voltage is a phenomenon that occurs frequently in actual industrial sites. If the grid voltage is unbalanced, THD increases due to voltage negative component, and low harmonic components appear in DC-link voltage, which ...
Ahmed G. Abo-Khalil, Ali M. Eltamaly
openaire +1 more source
Impact of unbalanced grid conditions on PV systems
IEEE PES General Meeting, 2010With more and more photovoltaic (PV) panels, energy storage devices and other small generators being put into service, it is necessary to integrate them into power systems. Grid integration provides a reliable means for customers to use renewable energy such as solar at its maximum and to use other sources as backup.
null Lingling Fan +2 more
openaire +1 more source
Unbalanced faults analysis in grid - Connected PV system
2014 IEEE International Conference on Power and Energy (PECon), 2014A search for replacement of non-renewable energy leads to a new founding that is renewable energy which is unlimited energy source. One of the renewable energy is solar energy where photovoltaic (PV) array is used to convert the energy from the sun to electrical energy. PV is widely use in the grid-connected system nowadays.
Listhianne Willy Anak Badi +3 more
openaire +1 more source
Wind Turbine Harmonics caused by Unbalanced Grid Currents
2007 Compatibility in Power Electronics, 2007For wind turbines that feed into public grids limits for voltage and current harmonics must be assured. To verify that the actual levels are valid, measurements are necessary. Problems can occur to determine which part of these harmonics has its origin in the wind turbine.
Klaus-Dieter Dettmann +2 more
openaire +1 more source
Nonsinusoidal power caused by measurements of grid impedances at unbalanced grid voltages
2008 International School on Nonsinusoidal Currents and Compensation, 2008At low-voltage level there is already a commercial measurement device that is able to identify the grid impedance in dependency of time and frequency. Since at the low-voltage level a four-wire system and at the medium-and high-voltage level a three-wire system is installed, the method to identify the grid impedance has to be varied.
null Trung Do Thanh +3 more
openaire +1 more source
Analysis of wind driven grid connected induction generators under unbalanced grid conditions
IEEE Transactions on Energy Conversion, 1994A wind driven induction generator feeding power to the grid has been analyzed under the abnormal condition of unbalanced grid voltages. Using the symmetrical component and double revolving field theory, appropriate equivalent circuits and model equations have been derived for the generating mode with suitable realistic modifications.
A.H. Ghorashi +3 more
openaire +1 more source
Stability analysis of grid-connected inverter under unbalanced grid
2023 IEEE 6th International Electrical and Energy Conference (CIEEC), 2023Pingyu Li, Bao Xie, Weike Zheng
openaire +1 more source
Control strategy for inverter in a micro-grid under unbalanced grid condition
2016 IEEE Conference on Technologies for Sustainability (SusTech), 2016Micro-grid is gaining momentum as it addresses grave concerns like climate change and energy security. This paper presents power flow control algorithm for voltage source inverter used in a micro-grid under unbalanced grid conditions. Energy Storage and local energy source are the key components of the micro-grid that is required to help stabilize grid.
L. Ashok Kumar, Sheeba Babu
openaire +1 more source
Circulating Current Suppression for MMC-HVDC under Unbalanced Grid Conditions
IEEE Transactions on Industry Applications, 2016Modular multilevel converter (MMC) is believed the most competitive solution for high-voltage direct current (HVDC) transmission using voltage source converters. Circulating current suppressing strategies based on proportional resonant (PR) controllers are widely used in MMC. This kind of strategies can effectively eliminate all the circulating current
null Jinyu Wang +3 more
openaire +1 more source
Inner Current Controls of Grid-Connected PV for Unbalanced Grid Conditions
2021 North American Power Symposium (NAPS), 2021Abdulhakim Alsaif +2 more
openaire +1 more source