Results 81 to 90 of about 27,637 (228)
Unbalanced voltage and harmonics are major challenges in a microgrid. Single- and two-phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid.
Ehsan Akbari, Abbas Zare Ghaleh Seyyedi
doaj +1 more source
Constant power loads (CPLs), interfaced through active rectifiers can be used for improving the stability of induction generator (IG)-based wind turbines under balanced grid voltage dips by providing the reactive power.
Marta Molinas, Nadeem Jelani
doaj +1 more source
Variable-Angle Phase-Shifted PWM for Multilevel Three-Cell Cascaded H-bridge Converters [PDF]
Multilevel cascaded H-bridge converters have become a mature technology for applications where high-power medium ac voltages are required. Normal operation of multilevel cascaded H-bridge converters assumes that all power cells have the same dc voltage ...
Freire Macías, Emilio +6 more
core +1 more source
MGM as a Large‐Scale Pretrained Foundation Model for Microbiome Analyses in Diverse Contexts
We present the Microbial General Model (MGM), a transformer‐based foundation model pretrained on over 260,000 microbiome samples. MGM learns contextualized microbial representations via self‐supervised language modeling, enabling robust transfer learning, cross‐regional generalization, keystone taxa discovery, and prompt‐guided generation of realistic,
Haohong Zhang +5 more
wiley +1 more source
Grid type energy storage has inertia support capability, and unbalanced grid voltage will cause grid type energy storage current fluctuation and active power fluctuation.
Li You +4 more
doaj +1 more source
ExaGridPF: A Parallel Power Flow Solver for Transmission and Unbalanced Distribution Systems
This paper investigates parallelization strategies for solving power flow problems in both transmission and unbalanced, three-phase distribution systems by developing a scalable power flow solver, ExaGridPF, which is compatible with existing high ...
Bachan, John, Chan, Cy, Wang, Bin
core +1 more source
Voltage dip generator for testing wind turbines connected to electrical networks [PDF]
This paper describes a new voltage dip generator that allows the shape of the time profile of the voltage generated to be configured. The use of this device as a tool to test the fault ride-through capability of wind turbines connected to the electricity
Abbesa +21 more
core +2 more sources
A large‐scale multiomic dataset (proteomic and metabolomic) comprising 3,060 plasma samples were analyzed to identify proteins, metabolites, pathways, and protein‐associated drugs linked to Alzheimer’s Disease (AD) independently of apolipoprotein E (APOE). AD was associated with a distinct molecular signature that captures.
Fuhai Li +22 more
wiley +1 more source
When the grid voltage is unbalanced, the positive and negative sequence components in the grid voltage cause grid current to be disordered. Under current balance control, proportional integral (PI) closed-loop control will increase the grid currents ...
Yunjun Yu, Zhongyang Wang, Xiaofeng Wan
doaj +1 more source
Engineered GM1 Intersects Between Mitochondrial and Synaptic Pathways to Ameliorate ALS Pathology
Amyotrophic Lateral Sclerosis (ALS) is a fatal neurodegenerative disease driven by genetic and molecular disruptions affecting energy balance, protein homeostasis, and stress responses in nerve cells. Studies using human and rodent models identified convergent defects in mitochondria and synaptic function.
Federica Pilotto +11 more
wiley +1 more source