Results 1 to 10 of about 406 (248)

Incremental dynamic analysis of underground subway station structure [PDF]

open access: yesE3S Web of Conferences, 2021
Incremental dynamic analysis constitutes the basis of seismic performance evaluation and seismic vulnerability assessment. In this paper, a typical two-story three-span subway station structure is selected as an example structure and its incremental ...
Liu Tong   +3 more
doaj   +3 more sources

Research on Seismic Performance of a Two-Story, Two-Span Underground Subway Station with Split Columns Based on the Quasi-Static Method

open access: yesApplied Sciences
The behavior of center columns in shallow-buried underground subway station structures resembles that of high-rise buildings. In both cases, these columns experience significant vertical loads during earthquake events and are susceptible to brittle ...
Zigang Xu   +3 more
doaj   +4 more sources

Characterization of Airborne Bacteria at an Underground Subway Station [PDF]

open access: yesApplied and Environmental Microbiology, 2012
ABSTRACT The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational ...
Dybwad, Marius   +3 more
core   +8 more sources

Research on Launching Technology of Shield Tunnel in Ho Chi Minh Metro Line 1 [PDF]

open access: yesArchives of Civil Engineering, 2021
The use of subway tunnel engineering technology has become more professional and refined with the growth of society and the advancement of science and technology. The initial construction process of a subway tunnel shield is the most critical part of the
Xuan Loi Nguyen   +5 more
doaj   +1 more source

Preliminary analysis of mechanical properties of subway station under fire after earthquake

open access: yesYantu gongcheng xuebao, 2022
As an important part of the urban underground infrastructure, the underground structures such as subway stations will cause great economic damage and casualties once they are subjected to earthquakes and earthquake-induced fires.
WANG Guo-bo 1, LIU Qiang 1, WANG Hong-jie 1, WANG Jian-ning 2, DONG Zheng-fang 3
doaj   +1 more source

Discussion On Prefabricated Assembly Plan Of Subway Underground Station

open access: yesIOP Conference Series: Earth and Environmental Science, 2021
Abstract Prefabricated assembly technology has become an important direction for the development of subway underground stations. Comprehensively considering the three factors of stress, waterproof and construction environment, this paper proposes a set of prefabricated and cast-in-place assembly plans for subway stations.
Huang Wei, Ren Meng
openaire   +1 more source

Optimal index of earthquake intensity measures for seismic design of underground frame structure of shallow-buried subway station

open access: yesYantu gongcheng xuebao, 2023
The optimal index of earthquake intensity measures required in the probabilistic seismic demand model for seismic design of the underground frame structure of shallow-buried subway station is studied.
JIANG Jiawei 1, 2, XU Chengshun 3, DU Xiuli 3, CHEN Guoxing 1, 2, XU Zigang 4
doaj   +1 more source

Large-scale cyclic-loading pushover test method and its verification for seismic damage of underground structures

open access: yesYantu gongcheng xuebao, 2023
It is difficult to effectively simulate the seismic damage characteristics of underground structures and their failure process in the current shaking table model tests.
YANG Jing 1, ZHUANG Haiyang 1, 2, WANG Wei 1, ZHANG Guangyu 1, CHEN Su 3
doaj   +1 more source

Experimental tests and theoretical analysis for mechanical behaviors of side wall opening construction in mined excavation subway station

open access: yesFrontiers in Earth Science, 2023
The connection of subway stations to surrounding underground spaces inevitably involves opening construction in the existing underground structure. The opening construction can strongly impact the existing underground structure when there is no reserved ...
Zhinan Hu   +3 more
doaj   +1 more source

Seismic response of subway station structure with concrete-filled-steel-tube middle columns

open access: yesYantu gongcheng xuebao, 2023
In order to improve the seismic performance of underground structures, the concrete-filled steel tube (CFST) middle column is usually used in the existing subway station structures.
ZHONG Zilan , GUO Qinglong , GUO Jiaxi , ZHANG Bu , ZHAO Mi
doaj   +1 more source

Home - About - Disclaimer - Privacy