Results 31 to 40 of about 114,417 (158)
Optimization of urinary dipstick pH: Are multiple dipstick pH readings reliably comparable to commercial 24-hour urinary pH? [PDF]
Purpose: Accurate measurement of pH is necessary to guide medical management of nephrolithiasis. Urinary dipsticks offer a convenient method to measure pH, but prior studies have only assessed the accuracy of a single, spot dipstick.
Joel E. Abbott +6 more
doaj +1 more source
Repeated Negative Urine Trypsinogen-2 Dipstick Test Rules Out Diagnosis of Post-ERCP Pancreatitis.
BACKGROUND A dipstick test for urine trypsinogen-2 has been used in the diagnosis of acute pancreatitis, but there are only a few studies exploring the effectiveness of this test for early diagnose of post-endoscopic retrograde cholangiopancreatography ...
M. Rainio +5 more
semanticscholar +1 more source
Evaluation of Urine Dipstick For Leukocyte Esterase Test For Diagnosis of Urinary Tract Infection
Background:General urine examination (GUE) and urine culture are the most requested tests by clinicians for patients with symptoms suggestive of urinary tract infections (UTI). However, they are laborious methods.
Shaima'a Rahem Al-Salihy
doaj +2 more sources
For disease surveillance and mapping within large-scale control programmes, RDTs are becoming popular. For intestinal schistosomiasis, a commercially available urine-dipstick which detects schistosome circulating cathodic antigen (CCA) in host urine is ...
Kariuki HC +5 more
doaj +1 more source
Our study aimed to evaluate the diagnostic performance of point-of-care nitrite and leukocyte esterase (LE) dipsticks in the diagnosis of suspected urinary tract infection (UTI) in infants
Jayasurya Suresh +4 more
semanticscholar +1 more source
Does Proteinuria Measured by Dipstick Method Reflect Reality in Patients with Preeclampsia?
Aim: The aim of our study is to compare the proteinuria levels measured by dipstick in complete urine analysis at admission with the proteinuria levels measured in 24-hour collected urine for patients hospitalized with a ...
Cenk Soysal, Mehmet Murat Işıkalan
doaj +1 more source
Background Overdiagnosis and overtreatment of urinary tract infection (UTI) with antibiotics is a concern. In older adults, diagnosis of UTI using near-patient urine tests (reagent strip tests, dipsticks) is advised against because the age-related ...
Emily Rousham +4 more
doaj +1 more source
Evaluation of methods for rapid microalbuminuria screening in kidney diseased patients [PDF]
Introduction. One of the criteria for chronic kidney disease detection is determination of microalbuminuria. Objective. This analysis was performed to evaluate accuracy of three useful methods for microalbuminuria detection in 24h urine collection and
Dajak Marijana +5 more
doaj +1 more source
Background There is a need for an easy and sensitive method for screening of urinary tract infections in young children. We set out to test whether a novel diaper-embedded urine test device is feasible and reliable in screening for urinary tract ...
Niko Paalanne +6 more
doaj +1 more source
Objective To report the diagnostic test accuracy of dipstick urinalysis for the detection of urinary tract infections (UTIs) in febrile infants aged 90 days or less attending the emergency department (ED). Design Retrospective cohort study.
Thomas Waterfield +10 more
semanticscholar +1 more source