Results 31 to 40 of about 10,897 (316)
Development and Testing of a 252 kV/2500 A-40 kA Multi-Break Bus-Coupler Fast Vacuum Circuit Breaker
It is effective to open the bus-coupler circuit breaker in case of a short-circuit fault. A fast vacuum circuit breaker (FVCB) is an ideal bus-coupler circuit breaker due to its high velocity.
Kui Ma +7 more
doaj +1 more source
Hybrid switching technologies such as zero voltage switching (ZVS) and zero current switching (ZCS) are widely accepted to protect DC power systems from different kinds of faults.
Zhuangxian Jiang +5 more
doaj +1 more source
One of the important directions of theoretical, computational and experimental research related to the improvement and development of new design elements of modern electrical devices, primarily medium voltage circuit breakers and contactors, is the study
Yevhen I. Baida +2 more
doaj +1 more source
DC Current Interruption Based on Vacuum Arc Impacted by Ultra-Fast Transverse Magnetic Field
In this paper, the effect of an external ultrafast transverse magnetic field (UFTMF) on a vacuum arc in the diffused mode has been studied. According to the results of studies, a novel approach for making a zero-crossing in a DC arc current has been ...
Ehsan Hashemi, Kaveh Niayesh
doaj +1 more source
DC interruption characteristic of vacuum circuit breaker
AbstractA high‐speed vacuum circuit breaker (HSVCB) has been investigated. HSVCB makes high‐frequency current superimposed on a fault current so that the current is forced to be zero and is interrupted. Its interruption performance is considered to be dependent on the rate of change of the current (di/dt). As a fundamental research, we investigated the
Hiromi Odaka +5 more
openaire +2 more sources
The generator circuit breaker is a special breaker located between a pumped storage machine and a step-up transformer. The first requirement for generator circuit breaker is to interrupt fault currents with delayed current zero, preventing the damage of ...
Weijie Wen +4 more
doaj +1 more source
INVESTIGATION OF MECHANICAL STRESSES IN THE DRIVE SHAFT OF MV VACUUM CIRCUIT BREAKER
Introduction. In the last 10-15 years a dominant position in the market of medium voltage circuit breakers, vacuum circuit breakers have taken in which as an actuator mono- or bistable actuators with permanent magnets are used.
E. I. Baida, B. V. Klymenko
doaj +1 more source
Among all circuit breaker faults, mechanical failures account for a considerable proportion, and online monitoring of their mechanical characteristics is of great practical significance.
Liting Weng +8 more
doaj +1 more source
Simulation study on modeling of vacuum arc characteristics and anode temperature rise in low-frequency vacuum interruption [PDF]
Low-frequency transmission technology has been widely used in medium- and long-distance electricity transmission scenarios such as offshore wind power transmission due to its advantages of low cost and strong ability to pool renewable energy.
Yanting Li +6 more
doaj +1 more source
High temperature circuit breaker [PDF]
Alternating current circuit breaker is suitable for reliable long-term service at 1000 deg F in the vacuum conditions of outer space. Construction materials are resistant to nuclear radiation and vacuum welding.
Edwards, R. N., Travis, E. F.
core +1 more source