Results 131 to 140 of about 38,596 (261)
The use of autologous connective tissue, such as pericardium or peritoneum, combined with controlled tissue treatment, has the potential to result in a more durable heart valve prosthesis than current commercial prostheses. ABSTRACT Introduction Valvular heart disease remains a leading cause of morbidity and mortality. Current biological and mechanical
Marvin Steitz +17 more
wiley +1 more source
Shear‐induced blood damage—including hemolysis, platelet and neutrophil injury, and von Willebrand factor (vWF) degradation—was evaluated for the BrioVAD and HM3 using an in vitro circulatory loop under clinically relevant conditions. Across 15 biomarkers (n > 6 per group), no significant differences were observed between the two devices.
Wenji Sun +9 more
wiley +1 more source
Leadless pacemaker implantation via right jugular approach in a patient with a bicaval valve system: a case report. [PDF]
Kuhnhardt K +4 more
europepmc +1 more source
This mixed methods study aimed to: (i) identify treatment expectations held by individuals with a ventricular assist device (VAD), (ii) assess the extent to which these expectations have been met, and (iii) examine how treatment expectations relate to VAD‐specific health‐related quality of life (HRQoL) ABSTRACT Objectives Treatment expectations ...
Simon Felix Zerth +10 more
wiley +1 more source
Unexpected course of urethroplasty in patient with penile prosthesis. [PDF]
Alnadhari I +6 more
europepmc +1 more source
Does Triplex Vascular Prosthesis Contribute to Reducing the Inflammatory Reaction after Surgical Repair of Abdominal Aortic Aneurysms? [PDF]
Fukunaga N, Matsuo T, Koyama T.
europepmc +1 more source
Blade shapes (leading‐edge geometry and thickness) in rotodynamic blood pumps were systematically evaluated. Thinner blades improve pump efficiency by reducing blockage effects, while neither blade thickness nor leading‐edge geometry shows clear hemocompatibility benefits. Overall, blade shape has a limited impact on hemocompatibility, indicating it is
Benjamin Torner +7 more
wiley +1 more source
Modified Subclavian Artery-to-Right Atrium Bypass Technique in a Patient on Chronic Hemodialysis With Central Venous Occlusion. [PDF]
Morjane Y +4 more
europepmc +1 more source
Extracorporeal albumin dialysis (OPAL) effectively reduces bilirubin and improves other laboratory markers in posthepatectomy liver failure, particularly in secondary forms. It may serve as a bridging therapy to support hepatic recovery in critically ill patients, although prospective studies are needed to confirm its impact on survival.
Dorian Marckmann +16 more
wiley +1 more source