Results 71 to 80 of about 435,363 (293)

Effectiveness of rTMS on Working Memory and Inhibitory Impairments in Patients With Post‐Stroke Executive Deficits

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Considerable efforts have been dedicated to developing effective treatments for post‐stroke executive impairment (PSEI), among which repetitive transcranial magnetic stimulation (rTMS) has shown great potential. This study aimed to investigate the therapeutic effects of high‐frequency rTMS on working memory (WM) and response ...
Mengting Lao   +6 more
wiley   +1 more source

Superluminal optical pulse propagation in nonlinear coherent media [PDF]

open access: yes, 2002
The propagation of light-pulse with negative group-velocity in a nonlinear medium is studied theoretically. We show that the necessary conditions for these effects to be observable are realized in a three-level $\Lambda$-system interacting with a ...
A. Dogariu   +31 more
core   +2 more sources

A Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller

open access: yesInternational Journal of Adaptive Control and Signal Processing, EarlyView.
Block Diagram of the Robust Adaptive One‐Sample‐Ahead Preview Super‐Twisting Sliding Mode Controller. ABSTRACT This article introduces a discrete‐time robust adaptive one‐sample‐ahead preview super‐twisting sliding mode controller. A stability analysis of the controller by Lyapunov criteria is developed to demonstrate its robustness in handling both ...
Guilherme Vieira Hollweg   +5 more
wiley   +1 more source

近断层速度脉冲型地震动纵向输入下综合管廊振动台试验

open access: yesDizhen xuebao
基于振动台试验,探讨了速度脉冲对综合管廊动力响应的影响,重点阐明了地震动速度脉冲特性如何影响综合管廊和周围土壤的地震行为。选取具有速度脉冲的实际地震动记录和合成的与实际地震动记录具有相同反应谱的无速度脉冲地震动时程,同时将其加速度幅值分别调整为0.10g,0.20g,0.30g作为输入,设计并开展了地震动纵向输入下的综合管廊振动台试验。基于试验数据分析了场地土体的地震反应变化规律、综合管廊结构的地震响应特征和土-结构相互作用效应。研究结果表明:① 土体在连续试验加载下结构发生变化 ...
Jian Chu   +5 more
doaj   +1 more source

Elevated levels of urine isocitrate, hydroxymethylglutarate, and formiminoglutamate are associated with arterial stiffness in Korean adults

open access: yesScientific Reports, 2021
Recent evidence suggests that cellular perturbations play an important role in the pathogenesis of cardiovascular diseases. Therefore, we analyzed the association between the levels of urinary metabolites and arterial stiffness. Our cross-sectional study
Ji-Hee Haam   +8 more
doaj   +1 more source

Doppler cooling with coherent trains of laser pulses and tunable "velocity comb"

open access: yes, 2011
We explore the possibility of decelerating and Doppler cooling of an ensemble of two-level atoms by a coherent train of short, non-overlapping laser pulses.
Andrei Derevianko   +5 more
core   +1 more source

Prediction of Surface Topography Parameters in Direct Laser Interference Patterning of Stainless Steel Using Infrared Monitoring and Convolutional Neural Networks

open access: yesAdvanced Engineering Materials, EarlyView.
This study presents an infrared monitoring approach for direct laser interference patterning (DLIP) combined with a convolutional neural network (CNN). Thermal emission data captured during structuring are used to predict surface topography parameters.
Lukas Olawsky   +5 more
wiley   +1 more source

Analysis of terahertz generation using tilted-pulse-fronts

open access: yes, 2018
A 2-D spatio-temporal analysis of terahertz generation by optical rectification of tilted-pulse-fronts is presented. Closed form expressions of terahertz transients and spectra in two spatial dimensions are furnished in the undepleted limit. Importantly,
Kärtner, Franz X., Ravi, Koustuban
core   +2 more sources

Investigation of Laser Ablation and Brush Pre‐Treatments for AlCu Cold Roll Bonding in Oxygen‐Free Conditions

open access: yesAdvanced Engineering Materials, EarlyView.
It is shown that laser ablation pretreatment under oxygen‐free conditions enables copper–aluminium bonding at significantly lower deformation degrees and improved properties compared to mechanical brushing. Laser ablation further increases interface contact area and induces favourable residual stress states and microstructural compatibility ...
Khemais Barienti   +11 more
wiley   +1 more source

P6.01 IMPLANTABLE PULSE WAVE VELOCITY SENSOR

open access: yesArtery Research, 2013
In case of vascular weakness or thrombosis stents are implanted and brace vessels from the inside to assure the proper blood flow. A widespread method to monitor the state of blood vessels in terms of their stiffness and diameter is to measure the pulse ...
A. Domnich, J. Schaechtele
doaj   +1 more source

Home - About - Disclaimer - Privacy