Results 71 to 80 of about 129,657 (313)

Influence of Surface Finish on the Tribological Performance of AlTiBN Coatings Deposited on Forming Tools

open access: yesAdvanced Engineering Materials, EarlyView.
Aluminum and nitride coatings are used in industry because they are hard, resist wear, and protect against oxidation. Adding boron can improve friction behavior and other properties. This study tests coatings on surfaces with different finishes. Results show smoother surfaces perform better, while rough ones wear faster, although coatings can reduce ...
Adrián Claver   +9 more
wiley   +1 more source

P6.01 IMPLANTABLE PULSE WAVE VELOCITY SENSOR

open access: yesArtery Research, 2013
In case of vascular weakness or thrombosis stents are implanted and brace vessels from the inside to assure the proper blood flow. A widespread method to monitor the state of blood vessels in terms of their stiffness and diameter is to measure the pulse ...
A. Domnich, J. Schaechtele
doaj   +1 more source

An assessment of pulse transit time for detecting heavy blood loss during surgical operation [PDF]

open access: yes, 2012
Copyright @ Wang et al.; Licensee Bentham Open. This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non ...
Lin, TY   +4 more
core   +1 more source

From Shear to Sound: Mechanics–Acoustics Mapping of TPMS Lattices

open access: yesAdvanced Engineering Materials, EarlyView.
Triply periodic minimal surface (TPMS) lattices are mapped across mechanical and acoustic performance, revealing that descriptors validated in compression fail under shear. First‐time comparison with trusses included. A transition from porous to resonance‐driven absorption emerges at 25% density.
Lucía Doyle   +3 more
wiley   +1 more source

All‐in‐One Analog AI Hardware: On‐Chip Training and Inference with Conductive‐Metal‐Oxide/HfOx ReRAM Devices

open access: yesAdvanced Functional Materials, EarlyView.
An all‐in‐one analog AI accelerator is presented, enabling on‐chip training, weight retention, and long‐term inference acceleration. It leverages a BEOL‐integrated CMO/HfOx ReRAM array with low‐voltage operation (<1.5 V), multi‐bit capability over 32 states, low programming noise (10 nS), and near‐ideal weight transfer.
Donato Francesco Falcone   +11 more
wiley   +1 more source

A Velocity Dealiasing Algorithm on Frequency Diversity Pulse-Pair for Future Geostationary Spaceborne Doppler Weather Radar

open access: yesAtmosphere, 2018
Velocity ambiguity is one of the main challenges in accurately measuring velocity for the future Geostationary Spaceborne Doppler Weather Radar (GSDWR) due to its short wavelength.
Xuehua Li   +5 more
doaj   +1 more source

Velocity Spectrum Imaging Using Velocity Encoding Preparation Pulses

open access: yesMagnetic Resonance in Medicine
ABSTRACT Purpose The goal of this article is to introduce a technique to measure the velocity distribution of water inside each voxel of an MR image. The method is based on the use of motion sensitizing gradients with changing first moment to encode velocity.
Luis Hernandez‐Garcia   +2 more
openaire   +4 more sources

Effect of inflammation on the relationship of pulse pressure and mortality in haemodialysis.

open access: yes, 2011
The effect of hypertension on mortality in haemodialysis patients is controversial and can be confounded by non-traditional risk factors like systemic inflammation. This study examined the effect of systolic blood pressure (SBP), diastolic blood pressure
Herzog, CA, Collins, AJ, Banerjee, D
core   +1 more source

Hot‐Film and Calorimetric Methods With Transient Heating for Measurement of High Biofluid Flow Rate

open access: yesAdvanced Functional Materials, EarlyView.
Accurate measurement of biofluid flow rate is vital for clinical diagnostics. We propose a transient heating strategy using short thermal pulses and peak temperature tracking to enhance the flow sensitivity of the hot‐Film and calorimetric methods. Simulations show how optimal heating time maximizes sensitivity across flow rates.
Yuanting Wei   +8 more
wiley   +1 more source

Association between increased arterial stiffness and clinical outcomes in patients with early sepsis: a prospective observational cohort study

open access: yesIntensive Care Medicine Experimental, 2019
Background Conduit arteries, especially the aorta, play a major role in ensuring efficient cardiac function and optimal microvascular flow due to their viscoelastic properties.
Sigita Kazune   +4 more
doaj   +1 more source

Home - About - Disclaimer - Privacy