Results 51 to 60 of about 4,736,339 (290)
Onasemnogene Abeparvovec in Patients With SMA: Interim Results of the RESTORE Registry in Japan
ABSTRACT Objective There are limited real‐world data regarding the safety and effectiveness of onasemnogene abeparvovec (OA; Zolgensma) infusion, a one‐time gene replacement therapy, for Japanese patients with spinal muscular atrophy (SMA). We aimed to improve understanding of the real‐world outcomes for OA in Japan.
Kayoko Saito +8 more
wiley +1 more source
High tidal volume ventilation is not deleterious in infant rats exposed to severe hemorrhage [PDF]
BACKGROUND: Both high tidal volume (VT) ventilation and hemorrhage induce acute lung injury in adult rodents. It is not known whether injurious ventilation augments lung injury in infant rats exposed to severe hemorrhage.
Nicholls, Philip K. +14 more
core +1 more source
Low‐voltage FIB‐SEM tomography combined with a image preprocessing pipeline improves phase contrast and enables reliable machine‐learning segmentation of conductive networks in lithium‐ion battery electrodes. Structural descriptors are extracted from segmented images, done semimanually and automated, and compared.
Lisa Beran +6 more
wiley +1 more source
Physical Modeling and Structural Properties of Small-Scale Mine Ventilation Networks
This work is devoted to the modeling and structural analysis of ventilation networks in small-scale mines using a physically oriented modeling method that ensures power conservation.
David-Fernando Novella-Rodriguez +2 more
doaj +1 more source
Calculating the work of breathing during mechanical ventilation
Left figure: Passive patient esophageal pressure (Pes) in cmH2O on x-axis versus tidal volume in ml on y-axis. Green dashed line represents the chest wall compliance Right figure: same patient actively breathing on pressure support ventilation. (Pes) in
Mia Shokry +3 more
core +1 more source
Architecture‐Driven Sensor Stability in Weft‐Knitted Engineering Textiles
Textile‐integrated sensor architectures are systematically compared to evaluate their electromechanical behavior under combined mechanical and environmental loading. Pocket‐based integration exhibits stable and reproducible signals, whereas tunnel‐based routing shows higher sensitivity accompanied by increased variability.
Adnan Maroof Khan +5 more
wiley +1 more source
A calibration model for mine ventilation network based on optimization theory was established to address the issue of manual repeated adjustment of air resistance and low consistency between simulated and measured results when using ventilation network ...
Fengliang WU, Tong WANG
doaj +1 more source
ABSTRACT Chitosan, a polysaccharide upcycled from biowaste, has long promised sustainable, biocompatible, and antimicrobial films and devices, an appeal reinforced by its recent regulatory recognition, with several chitosan‐based antibacterial dressings gaining clearance through the Food and Drug Administration's 510(k) pathway.
Jacopo Nicoletti +16 more
wiley +1 more source
In order to eeproduced as much as possible the disaster processes such as air volume fluctuations, airflow reversal, abnormal airflow temperature, the spread of toxic and harmful smoke, and the decrease in oxygen volume fraction in the ventilation ...
Wei LI, Yanqing LIU, Lang ZHANG
doaj +1 more source
To determine the dynamic matching of a mine ventilation system to onsite demands of automatic adjustment, we analyze the principle of air volume supply and demand matching and a linkage control method.
Kai WANG +6 more
doaj +1 more source

