Results 11 to 20 of about 7,424,509 (170)
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen +7 more
doaj +2 more sources
As voltage measuring devices are widely used in the high voltage power system with a primary‐secondary‐fusion structure, electronic voltage transformers are directly connected to the primary conductor and would face much more serious electromagnetic ...
Houda Zhu +5 more
doaj +2 more sources
Abstract The Internet of Things is emerging as a crucial technology in aiding humans and making their lives easier. Among the human population, a large percentage of people suffer from disabilities resulting in challenges in everyday life particularly people with visual disabilities.
Hania Tarik +8 more
wiley +1 more source
Protection against transient overvoltage in precision AC-DC measurement system [PDF]
: Reduction in size and improvement of sensitive margins in modern semiconductor devices makes them increasingly susceptible to stress and subsequent damage caused by the overvoltage.
Kgakatsi, Thato E. +3 more
core +1 more source
The insulation system’s dielectric of the electric motor is very often subjected to severe electrical stress generated by the high dv/dt seen at the machine’s terminals.
Davide D’Amato +5 more
doaj +1 more source
Transfer Function Based Modeling of the Air-Cored Transformers for Very Fast Transient Overvoltage Studies [PDF]
In this paper, to calculate overvoltage in air-cored transformer windings under very fast transient overvoltage, firstly, the voltage transfer functions are calculated which are measured by network analyser or calculated from the distributed parameters ...
Esmaiilzadeh, S. +4 more
core +1 more source
Design of a novel transmission circuit of transient electromagnetic instrument
A transmission circuit of transient electromagnetic instrument based on FPGA was designed in order to improve measurement accuracy of transient electromagnetic instrument. Drive circuit of the transmission circuit was designed with module EXB841 to drive
XU Yakun +3 more
doaj +1 more source
Assessment of very fast transient overvoltage (VFTO) requires good knowledge of the behavior of gas-insulated substation when subjected to very high frequencies.
Muresan Alexandru +4 more
doaj +1 more source
Electrical equipment and supply cables demand a better quality of supply, with the recent advancements in integrated sensitive solid-state controls.
Earl A. R. L. Pannila +1 more
doaj +1 more source
Analysis of influential factors in determining very fast transient overvoltages of GIS substations [PDF]
High voltage Gas Insulated Substation (GIS) is threatened by Very Fast Transient Overvoltage (VFTO) which is high amplitude and high frequency transient within the range from 100 kHz up to 50 MHz in power systems. Operation of Disconnecting Switch is the
Nourirad, Ghasem +5 more
core +1 more source