A Novel Digital Twin Platform for Accelerating Power Systems Restoration
Hardware Architecture Design of DT System in Laboratory. ABSTRACT With the global energy structure transforming towards the goal of net zero emissions, the penetration of an inverter‐based resource (IBR) in power systems is increasing. This transformation poses two critical challenges: the system post blackout restoration process becomes extremely ...
Yiliang Fan +8 more
wiley +1 more source
© 1994-2012 IEEE. This paper investigates the feasibility of a cost effective method to prevent internal resonance in power transformers connected to gas insulated substation (GIS) due to very fast transient overvoltage (VFTO) within the GIS.
Abu-Siada, Ahmed +3 more
core +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
Modelagem de transformadores em função da frequência [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica.Os transformadores desempenham um papel importante nos sistemas elétricos. Ao longo do tempo as técnicas de construção e
Januário, Marconi
core
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
This study analyses a gas insulated switchgear explosion accident caused by a failure of the circuit breaker (CB) in a thermal power plant, which resulted in the explosion of the CB and the burning of the potential transformer (PT).
Xun Zhang +6 more
doaj +1 more source
Power plant lightning overvoltage protection of low voltage power electronics [PDF]
The effects of direct lightning strike and flashover strike to 400kV system of nuclear power plant were inspected for perspective of low voltage power electronic devices. Protection methods were simulated with PSCAD transient simulator.
Pasonen, Riku
core +1 more source
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more
wiley +1 more source
Simulation and Test Study on Very Fast Transient Overvoltage in 1000kV GIS Substation [PDF]
Disconnector switching in gas insulated switchgear (GIS) generates very fast transient overvoltage (VFTO). VFTO may damage the insulation of GIS equipment. This paper studies the VFTO of a 1000kV GIS substation. The simulation models are obtained according to the configuration of GIS. Operation modes of disconnector were summarized. The characteristics
Bin Han +5 more
openaire +1 more source