Research on VFTO Simulation Analysis of 1000 kV GIS Test Circuit Considering Dynamic Arcing Model
IEEE transactions on industry applications, 2022In the research process of very fast transient overvoltage (VFTO), the accuracy of the switching arc model largely determines the calculation results of VFTO.
Yanze Zhang +8 more
semanticscholar +1 more source
Analysis of VFTO in 1000kV GIS
2020 6th Global Electromagnetic Compatibility Conference (GEMCCON), 2020With the development of UHV (Ultra High Voltage) transmission technology, GIS(Gas Insulated Substation) is usually used at all levels of substations, but it will produce VFTO (Very Fast Transient Overvoltage)when operating its isolating switch. It has the characteristics of large amplitude, high frequency and fast fluctuation.
openaire +1 more source
Lumped parameter modeling of transformer windings under VFTO
2011 4th IEEE International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications, 2011Very fast transient overvoltage (VFTO) is very dangerous for the transformer which is directly connected to gas insulated substations (GIS). In order to study the voltage distribution in transformer windings under VFTO, a new model named the Piecewise Lumped Parameter (PLP) model is proposed.
Juan Du +4 more
openaire +1 more source
Other Conferences, 2023
Lightning impulse overvoltage is the main factor to determine the insulation level of substation, and the insulation coordination between the insulation level of the protected electrical equipment and the arrester of the protection device is the most ...
Ruming Feng +8 more
semanticscholar +1 more source
Lightning impulse overvoltage is the main factor to determine the insulation level of substation, and the insulation coordination between the insulation level of the protected electrical equipment and the arrester of the protection device is the most ...
Ruming Feng +8 more
semanticscholar +1 more source
Study on the transient characteristics of 1100kV VFTO
2017 4th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST), 2017The very fast transient overvoltage (VFTO) generated by switching disconnector (DS) in gas insulated substation (GIS) with the features of high amplitude, short rise-time and complex frequency components, may cause damage to the insulation of electrical equipment.
Wu Xixiu +4 more
openaire +1 more source
Research of VFTO in 110kV minimized GIS
2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2015110kV minimized gas insulated substation (GIS) has been widely used in China, due to its great electrical properties. The closing or opening operation of disconnector switches (DS) and circuit breaker (CB), and single-phase ground fault are all probable to cause the very fast transient overvoltage (VFTO), which is a threat to the power system. Compared
He Qifei, Hao Zhiguo, Guo Jie
openaire +1 more source
Design of Triggering Device for VFTO Measurement System
Advanced Materials Research, 2012Very fast transient overvoltage (VFTO) can be generated during the operation of disconnect switch (DS). Especially in ultra high voltage (UHV) gas insulated substation (GIS), VFTO is a threat to the safety of the power system equipment. It is very important to measure VFTO waveforms accurately.
Gong Chang Yue +3 more
openaire +1 more source
Research on VFTO Characteristics of Substation using GIL-GIS-oil/SF6 Bushing Structure
IEEE International Conference on High Voltage Engineering and Application, 2022GIL is one of the important ways to connect GIS substations through existing overhead lines in urban substations, and GIS is directly connected to the main transformer through oil/SF6 bushings, which is one of the important means to make the substation ...
Junfei Wang, X. Jiang, Lei Wang, Han Li
semanticscholar +1 more source
Implementation of Radiation and Soil Losses in VFTO Simulation by Frequency-Domain TL Model
IEEE Transactions on Power Delivery, 2022Transmission line (TL) models are widely used within the simulation of the very fast transient over-voltages (VFTO) for gas-insulated substations (GISs); however, due to quasi-TEM approximation and model complexity, energy losses related to bushing ...
Jun Zhao +6 more
semanticscholar +1 more source
Calibration of VFTO bushing sensor based on convolution model
2009 IEEE Intrumentation and Measurement Technology Conference, 2009Disconnector switching operations in large gas insulated switchgear (GIS) systems may cause very fast transients overvoltages (VFTO), which produce dielectric stress to transformer connecting with the disconnector. A VFTO bushing sensor is developed to measure the VFTO at the transformer entrance. Since the high frequency ratio of the bushing sensor is
Guo-ming Ma +3 more
openaire +1 more source