Study on the characteristics of the potential rise of shell under VFTO in the GIS pumped storage power station

open access: yesJournal of Physics: Conference Series, 2022
Compared with the traditional GIS station, complex wiring and operation mode of pumped-storage plant diversity, working condition of frequent transformation, makes the plant to produce very fast transient overvoltage (VFTO) probability increase greatly ...
Chao Kang   +3 more
semanticscholar   +1 more source

Design of a New Busbar for VFTO Suppression and Analysis of the Suppression Effect

open access: yesElectronics
Very fast transient overvoltage (VFTO) is characterized by short wavefront time, high amplitude and wide frequency. VFTO poses a threat to the safe operation of power equipment.
Huan Wang   +4 more
semanticscholar   +1 more source

Simulation and analysis of a gas insulated switchgear explosion accident caused by a failure of high‐voltage circuit breaker in a thermal power plant

open access: yesThe Journal of Engineering, Volume 2019, Issue 4, Page 3418-3424, April 2019., 2019
This study analyses a gas insulated switchgear explosion accident caused by a failure of the circuit breaker (CB) in a thermal power plant, which resulted in the explosion of the CB and the burning of the potential transformer (PT). Through X‐ray detection and disassemble examination of the damaged CB, it is found that the A‐phase moveable contact was ...
Xun Zhang   +6 more
wiley   +1 more source

Modeling of Common Mode Interference of Secondary Side of Potential Transformer in VFTO Excitation

open access: yesShanghai Jiaotong Daxue xuebao
Very fast transient overvoltage (VFTO) is generated during the operation of isolation switches and circuit breakers in substations, which can affect the safe and reliable operation of power secondary equipment through cable transmission and spatial ...
PANG Fubin, JI Jianfei, WU Xianqiang, ZHOU Mengxia, YAN Wei, XU Dong
doaj   +1 more source

The electromagnetic effect study of GIS enclosure under high‐frequency electromagnetic pulse

open access: yesThe Journal of Engineering, Volume 2019, Issue 16, Page 2837-2841, March 2019., 2019
In gas insulated switchgear (GIS) substation, due to the operation of disconnect switch and circuit breaker, as well as short‐circuit fault, SF6 will break down very rapidly. The superposition of refraction and reflection of high‐frequency travelling waves will cause the very fast transient electromagnetic pulse (EMP).
Shu Chen   +6 more
wiley   +1 more source

Research on Improved Arc Model of Isolating Switch and VFTO Characteristics

open access: yes, 2022
The simulation of very Fast Transient overvoltage (VFTO) requires an accurate isolating switch arc model. Based on gas discharge theory, the trend of electron number in the gap is analyzed by particle continuity equation simulation.
Zhuang-zhuang Yang
semanticscholar   +1 more source

New equivalent circuit model of UHVDC converter transformer winding for surge propagation investigation

open access: yesThe Journal of Engineering, Volume 2019, Issue 16, Page 2921-2925, March 2019., 2019
An accurate computational model of transformer winding for potential distribution analysis under impulse voltage is very important for the design of transformer inter‐turn insulation, especially for large capacity transformers such as ultrahigh‐voltage DC (UHVDC) converter transformer.
Shuang He   +7 more
wiley   +1 more source

The Study of VFTO Distribution in the Insulation System of IOCT Used in Traction Network

open access: yesEnergies, 2022
The FDS (Frequency-domain Dielectric Spectroscopy) of oil-immersed insulation paper, and semi-conductive paper with different moisture content, has been measured.
Zhonghuan Su   +5 more
semanticscholar   +1 more source

A novel GIS breakdown location method based on natural frequency of transient voltage

open access: yesHigh Voltage, Volume 10, Issue 4, Page 856-875, August 2025.
Abstract During on‐site withstand voltage tests of gas‐insulated switchgears (GIS), once a breakdown occurs, it is hard to locate the breakdown position due to the intricate branch structures and minimal breakdown energy. The existing methods may require the placement of a large number of sensors with unsatisfactory accuracy, which adversely affects ...
Qiang Sun   +9 more
wiley   +1 more source

Diagnostic analysis and protective measures of transient ground potential rise in a 1000 kv UHV substation

open access: yesThe Journal of Engineering, Volume 2019, Issue 16, Page 1144-1148, March 2019., 2019
With the continuous expansion of power grid capacity and growth of voltage levels, the transient ground potential rise (GPR) caused by the switchgear operation has become great threaten to the safety of the grid. In the startup operation of 500 kV part of Taizhou 1000 kV ultra‐high voltage (UHV) substation, the electromagnetic lock installed in the ...
Fubin Pang   +3 more
wiley   +1 more source