A Review of Research Progress in Very Fast Transient Overvoltage (VFTO) Suppression Technology
The very fast transient overvoltage (VFTO) is characterized by steep wavefronts, high amplitude, and wide spectrum. These characteristics can lead to partial discharges or insulation breakdowns in potted insulators, which can lead to localized ...
Huan Wang +3 more
doaj +2 more sources
The switching operation of gas insulated switchgear (GIS) disconnector will produce multiple random spark discharges between the gas gaps of the disconnector.
Jiangong Zhang +7 more
core +2 more sources
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Zifan Dong +7 more
core +2 more sources
Influence of Switching Conditions on the VETO Magnitudes in a GIS [PDF]
Estimation of very fast transient overvoltage (VFTO) has been carried out using EMTP for various switching conditions in a 420 kV gas-insulated substation (GIS). The variation of the VFTO peak along the GIS bus nodes for disconnector and circuit breaker switching operations, as well as the variation of VFTO peak with different magnitudes of trapped ...
Kumar, VV, Thomas, JM, Naidu, MS
openaire +3 more sources
The Optimization Design of VFTO Measuring Method
Whether VFTO can be fast accurate measured becomes an important index of GIS substation equipment safety. The research in this article used the optical voltage measuring method, through the simulation results of single photon road to analyze the advantages and disadvantages, furthermore the double optical path method was put forward, and by the ...
Xue-geng CHEN +3 more
openaire +3 more sources
Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage
In this paper, a withstand voltage test platform of 40.5‐kV vacuum circuit breaker was established to obtain the effects of the contact spacing and loop and inrush currents of vacuum circuit breaker on the number of restrike, the wavefront steepness of the breakdown voltage, and the breakdown duration.
Jixing Sun +8 more
wiley +1 more source
A low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement
Abstract Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and low‐cos t self‐trigger method for transient measurement is proposed.
Hao Liu +8 more
wiley +1 more source
Abstract The collectors of electronic transformers has the problem of electromagnetic incompatibility under the operation of disconnecting switches, which limits their wide application in smart grids. To evaluate the maximum level of disturbance that collectors are able to withstand in the stochastic process of switching operation, this work introduces
Qi Wang +6 more
wiley +1 more source
In recent years, gas‐insulated switchgear (GIS) substations have become widely used in power systems. Due to their compact structure, extremely high oscillation frequencies are prone to extremely high oscillation transient overvoltages or very fast transient overvoltages (VFTOs) when the isolating switch or circuit breaker is operated.
Caiquan Wen +8 more
wiley +1 more source
When a very fast transient overvoltage (VFTO) propagates in a high‐voltage bus, the capacitive voltage transformer (CVT) causes considerable interference on its secondary side, which will affect the normal operation of the secondary equipment. In this article, a CVT equivalent calculation circuit model was established, and the disturbance voltage of ...
Hanliang Lin +6 more
wiley +1 more source