Results 61 to 70 of about 9,838,650 (248)

Visual Fields at Presentation and after Trans-sphenoidal Resection of Pituitary Adenomas

open access: yesJournal of Ophthalmic & Vision Research, 2011
Purpose: To evaluate visual field changes in patients with pituitary adenomas following trans-sphenoidal surgery. Methods: Eighteen patients with pituitary adenomas underwent a complete ophthalmic assessment and visual field analysis using the Humphrey ...
Renu Dhasmana   +4 more
doaj  

Visual field defects in children with brain tumors

open access: yesBMC Ophthalmology
Introduction Visual field defects (VFDs) are detected in up to 25% of children with brain tumors and early identification of VFDs is crucial for timely treatment and vision preservation.
Anna Boethun   +5 more
doaj   +1 more source

Rapidly Solidified High‐Strength Invar 36 Prepared by Planar‐Flow Melt Spinning

open access: yesAdvanced Engineering Materials, EarlyView.
The Invar 36 alloy was rapidly solidified using the planar‐flow melt‐spinning technique. Ribbon samples with thicknesses ranging from 20 to 160 mm were produced. As the grain size of the ribbon decreased to sub‐micron levels, the hardness increased by more than 2 times.
Bekir Akgül, Mehmet Kul
wiley   +1 more source

Java code for simulation of visual field defects

open access: yes, 2018
Open-source Java code for simulating visual field defects during testing of normal ...
Optometry, Tsamis, Manos
core   +1 more source

Anterior Visual System Defects

open access: yes, 1977
Optic Nerve-Clinical hallmarks of optic nerve disease 1. Decreased visual acuity 2. Marcus Gunn pupillary phenanenon 3. Field defects a. Central scotoma. b. Cecocentral scotoma c. Altitudinal arcuate field defect 4. Optic palor, papillitis, opticociliary
Norman J. Schatz
core  

Visual Field Defects in Chiasmal Lesions

open access: yes, 2021
Classic teaching states that compression of the optic chiasm impacts decussating nasal retinal axons producing a bitemporal hemianopia (BTH). In fact, visual field defects resulting from chiasmal lesions are quite variable1.
Laura Donaldson; Arshia Eshtiaghi; Edward Margolin
core  

Enhancement of the Through‐Thickness Electrical Conductivity of Carbon‐Fiber‐Reinforced Plastics Using Large Graphite Particles

open access: yesAdvanced Engineering Materials, EarlyView.
To enhance through‐thickness conductivity without sacrificing impregnation, large spherical graphite particles are intentionally employed in a low‐viscosity resin. Unlike finer conductive fillers, these particles remain outside the fiber bundles and accumulate in resin‐rich interlaminar regions during molding.
Keito Hosoe   +6 more
wiley   +1 more source

Comparison of the 24-2 and 10-2 SITA standard visual field strategies in patients with early-stage primary open-angle glaucoma and glaucoma suspects

open access: yesThe Pan-American Journal of Ophthalmology
Purpose: To compare the effectiveness of the 24-2 and 10-2 SITA Standard (SS) visual field strategies in detecting central defects in patients with early-stage primary open-angle glaucoma (POAG) and glaucoma suspects.
Fabian Bogado   +3 more
doaj   +1 more source

Impact of the Process Atmosphere During Hot Isostatic Pressing on the Near‐Surface Composition of an Additively Manufactured Austenitic High‐Interstitial Steel

open access: yesAdvanced Engineering Materials, EarlyView.
A high interstital austenitic steel is additively manufactured and postdensified by HIP to eliminate gas porosity. Thereby, the loss of N and Mn in Ar HIP atmosphere is investigated. Further, HIP using N2 atmosphere is investigated which led to excessive nitride formation.
F. Großwendt   +4 more
wiley   +1 more source

Prognosis of Visual Field Defects in Stroke

open access: yes, 2013
Stroke is the leading neurologic cause of visual impairment. Literature dealing with visual field recovery in cerebral strokes is surprisingly small. The aim of this study was to determine the prognosis of visual field defects due to strokes involving ...
Nayan P. Desai, MD; A. Hammad, MD; L. Dominquez; D. Snider; E. Eggenberger, DO
core  

Home - About - Disclaimer - Privacy