Results 111 to 120 of about 1,781,037 (346)

Visual Cue Integration for Small Target Motion Detection in Natural Cluttered Backgrounds [PDF]

open access: yesarXiv, 2019
The robust detection of small targets against cluttered background is important for future artificial visual systems in searching and tracking applications. The insects' visual systems have demonstrated excellent ability to avoid predators, find prey or identify conspecifics - which always appear as small dim speckles in the visual field.
arxiv  

Integration of visual stimuli by the crayfish central nervous system [PDF]

open access: yes, 1967
For the crayfish, properties of visually reacting interneurone types in the optic nerve are described on the basis of single-unit analysis. Sustaining fibres show: (a) ‘surround’ inhibition over the whole retina, including the excitatory field; (b) ‘on’
Wiersma, C. A. G., Yamaguchi, T.
core  

Surface dose analysis and dosimetric comparison of Halcyon versus Truebeam in breast cancer radiotherapy: An OSL dosimetry study

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Breast cancer is a neoplastic disease with high prevalence among women. Radiotherapy is one of the principal treatment modalities for this disease, but it poses significant challenges. This study aimed to compare and evaluate the technical and dosimetric performance of conventional C‐arm linac systems and a new design, Halcyon, in the ...
Mustafa Çağlar   +8 more
wiley   +1 more source

How Does the Cerebral Cortex Work? Developement, Learning, Attention, and 3D Vision by Laminar Circuits of Visual Cortex [PDF]

open access: yes, 2003
A key goal of behavioral and cognitive neuroscience is to link brain mechanisms to behavioral functions. The present article describes recent progress towards explaining how the visual cortex sees.
Grossberg, Stephen
core   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Perceived length in the central visual field: evidence for visual field asymmetries

open access: yesVision Research, 2001
Visual performance for judging the length of a simultaneously presented pair of radial lines, reciprocally opposed by 180 degrees at a central fixation point, was assessed for 24 radial positions of test lines, for three viewing conditions (binocular, left and right monocular) and five different standard line sizes (1.43-7.13 degrees ).
Jocelyn Faubert, Sérgio Sheiji Fukusima
openaire   +3 more sources

Clinical validation of myOSLchip: A beryllium oxide optically stimulated luminescent dosimeter (OSLD) system in radiotherapy dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract In radiation oncology, inter‐fractional dosimetry using optically stimulated luminescent detectors (OSLDs) ensures accurate plan delivery and patient safety. RadPro International GmbH's myOLSchip system, featuring a beryllium oxide (BeO) OSL dosimeter, reader, and eraser, was characterized and calibrated with a Varian Truebeam for in‐vivo ...
Heath Davis   +3 more
wiley   +1 more source

Evaluation of internal target volume of abdominal tumors using cine‐MRI

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The detailed anatomy visualization with magnetic resonance (MR)‐guided radiotherapy is particularly attractive for abdominal treatments, but patient respiratory motion can compromise image quality. The “navigator technique” produces high‐quality 3D images, triggered by diaphragm displacement, in exhale phase only.
Jessica Lye   +8 more
wiley   +1 more source

Visual field examination method using virtual reality glasses compared with the Humphrey perimeter

open access: yesClinical Ophthalmology, 2017
Stylianos Tsapakis, Dimitrios Papaconstantinou, Andreas Diagourtas, Konstantinos Droutsas, Konstantinos Andreanos, Marilita M Moschos, Dimitrios Brouzas 1st Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, Greece ...
Tsapakis S   +6 more
doaj  

Glaucoma and its association with obstructive sleep apnea: A narrative review

open access: yesOman Journal of Ophthalmology, 2016
Obstructive sleep apnea (OSA) is one of the systemic risk factors for glaucoma which causes irreversible visual field (VF) damage. We reviewed the published data of all types of studies on the association between these two conditions and papers regarding
Aditya Chaitanya   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy