Results 81 to 90 of about 4,584,652 (321)
Large well-relaxed models of vitreous silica, coordination numbers and entropy
A Monte Carlo method is presented for the simulation of vitreous silica. Well-relaxed networks of vitreous silica are generated containing up to 300,000 atoms.
A.C. Wright+23 more
core +2 more sources
A tailored bio‐targeted catalytic strategy based on a bacteria‐specific artificial biocatalyst (MoS2/Fe@mercaptophenylboronic acid@hyaluronic acid, MFBH) is proposed for treating bacterial endophthalmitis. This strategy exhibits high‐efficiency peptidoglycan‐targeted bactericidal efficacy in vivo following a single intravitreal injection of an ...
Caixia Sun+9 more
wiley +1 more source
The article presents the results of studying the levels of amino acids in the vitreous body of rats with rhegmatogenous retinal detachment at different stages of modeling the pathology (on the 3rd, 5th and 7th day).
H. Levytska+4 more
doaj +1 more source
Silicone oil has been the only long-term vitreous substitute used in the treatment of retinal detachment since 1962 by Cibis. Nevertheless, its effects on retinal vascular morphology and oxygen supply to the retina are ambiguous in current research.
Wei Yang+8 more
semanticscholar +1 more source
Iron‐induced lipid peroxidation of phosphatidylethanolamine (PE) species is the key driver of ferroptosis. The authors discovered that PHOSPHO1 lowers the level of PE in retinal pigment epithelial cells thus reducing the formation of lipid peroxides. Lowering PE levels can also prevent the creation of autolysosomes, reduce the production of free iron ...
Zhiyang Chen+19 more
wiley +1 more source
VITREOUS BODY STRUCTURES INVESTIGATION USING THE «VITREOCONTRAST» SUSPENSION
Purpose. To develop a new method of vitreous body (VB) preparation with the isolate contrasting and separation of the VB structures (canals, cisterns, and their anastomosis).Material and methods. The research was performed in 20 cadaver donor eyes.
N. M. Kislitsyna+3 more
doaj
Microbiological study on foreign body and vitreous samples of patients with intraocular foreign body
Objective To evaluate the relationship between the microbiological results of the vitreous humor and those of foreign body specimens in patients with intraocular foreign body (IOFB).
Seyed Ali Tabatabaei+7 more
doaj +1 more source
High-temperature, high-pressure optical cell [PDF]
The invention is an optical cell for containment of chemicals under conditions of high temperature and high pressure. The cell is formed of a vitreous silica tube, two optical windows comprising a vitreous silica rod inserted into the ends of a tube, and
Harris, R. P.+2 more
core +1 more source
Magnetically Controllable and Degradable Milliscale Swimmers as Intraocular Drug Implants
Magnetically controllable degradable milliscale swimmers (MDMS) offer a promising alternative to commercial intraocular drug implants, reducing complications like implant dislocation and uncontrolled drug release. MDMS achieve high velocities in ocular environments, enable real‐time imaging, and deliver drugs effectively without disrupting retinal ...
Erdost Yildiz+8 more
wiley +1 more source
Optical coherent tomography in diagnoses of peripheral retinal degenarations
Purpose: Studying the capabilities of optical coherence tomography (RTVue-100, OPTOVUE, USA) in evaluation of peripheral retinal degenerations, vitreoretinal adhesions, adjacent vitreous body as well as measurement of morphometric data.Methods: The study
O. G. Pozdeyeva+6 more
doaj +3 more sources