Results 11 to 20 of about 29,680 (229)

COMP Report: Patient-specific quality assurance practices in Canadian radiotherapy-results from a national survey. [PDF]

open access: yesJ Appl Clin Med Phys
Abstract Patient‐specific quality assurance (PSQA) is an essential component of modern radiotherapy, ensuring safe and accurate delivery of increasingly complex treatments. Given its resource‐intensive nature and the availability of evolving approaches, examining how PSQA is implemented and optimized across Canada is important to inform best practices.
Tran MN   +7 more
europepmc   +2 more sources

Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology

open access: yesTechnology in Cancer Research & Treatment, 2021
Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy.
Jianjian Qiu PhD   +3 more
doaj   +1 more source

Proton beam therapy in paediatric cancer: Anticipating the opening of the Australian Bragg Centre for Proton Therapy and Research

open access: yesJournal of Medical Imaging and Radiation Oncology, EarlyView., 2023
Summary Proton Beam Therapy (PBT) has the potential to improve paediatric cancer care by reducing radiation exposure and thus long‐term toxicities. Ethical concerns and debates surrounding the treatment, such as eligibility and accessibility, are ongoing in Australia. The Australian Bragg Centre for Proton Therapy and Research (ABCPTR) (named after Sir
Jeremy Khong   +10 more
wiley   +1 more source

Dosimetric effects of sectional adjustments of collimator angles on volumetric modulated arc therapy for irregularly-shaped targets. [PDF]

open access: yesPLoS ONE, 2017
To calculate an optimal collimator angle at each of sectional arcs in a full-arc volumetric modulated arc therapy (VMAT) plan and evaluate dosimetric quality of these VMAT plans comparing full-arc VMAT plans with a fixed collimator angle.Seventeen ...
Beom Seok Ahn   +5 more
doaj   +1 more source

Establishment of criteria for gamma-analysis of individual dose distributions during verification of radiotherapy high-tech treatment plans for cancer patients

open access: yesВесці Нацыянальнай акадэміі навук Беларусі: Серыя фізіка-тэхнічных навук, 2022
A typical process for verification of treatment plans in intensity-modulated radiation therapy is described. The main errors and uncertainties that arise in the course of planning dose distribution and in the process of dose delivery are listed.
M. N. Piatkevich   +2 more
doaj   +1 more source

Dosimetric Comparison between High Dose Rate Brachytherapy Boost and Volumetric Arc Therapy Boost in Locally Advanced Cancer Cervix

open access: yesAsian Journal of Oncology, 2021
Concurrent chemoradiotherapy is considered the standard treatment for the locally advanced cancer cervix (LACC). Radiotherapy is commonly administered by a three-dimensional conformal radiotherapy (3DCRT) approach followed by brachytherapy (BT).
Hanady Hegazy   +3 more
doaj   +1 more source

Multicriteria optimization informed VMAT planning [PDF]

open access: yesMedical Dosimetry, 2014
We developed a patient-specific volumetric-modulated arc therapy (VMAT) optimization procedure using dose-volume histogram (DVH) information from multicriteria optimization (MCO) of intensity-modulated radiotherapy (IMRT) plans. The study included 10 patients with prostate cancer undergoing standard fractionation treatment, 10 patients with prostate ...
Huixiao, Chen   +2 more
openaire   +2 more sources

Automatic feathering algorithm for VMAT craniospinal irradiation: a comprehensive comparison with other VMAT planning strategies [PDF]

open access: yesPhysica Medica, 2021
In craniospinal irradiation, field matching is very sensitive to intrafraction positional uncertainties in cranio-caudal direction, which could lead to severe overdoses/underdoses inside the planning target volume. During the last decade, significant efforts were made to develop volumetric-modulated arc therapy strategies, which were less sensitive to ...
Michele, Maddalo   +4 more
openaire   +2 more sources

Transition from 3D conformal to modern modulated craniospinal radiotherapy

open access: yesSouth African Journal of Oncology, 2022
Background: Achieving optimal tumour coverage during craniospinal irradiation (CSI) is a challenge. Whilst several critical organs are at risk of radiation-induced toxicity, if target volume structures like the cribriform plate receive less than 95% of ...
Hamida Fakira   +3 more
doaj   +1 more source

A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma [PDF]

open access: yesIranian Journal of Medical Physics, 2020
Introduction: The study was conducted to compare volumetric-modulated arc therapy (VMAT) with intensity-modulated radiation therapy (IMRT) in patients with locally advanced rectal cancer (LARC).
Eman Eldebawy   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy